The largest database of trusted experimental protocols

Agilent 1100 hplc dad

Manufactured by Agilent Technologies
Sourced in United States

The Agilent 1100 HPLC-DAD is a high-performance liquid chromatography (HPLC) system that incorporates a diode-array detector (DAD). It is designed for analytical and preparative chromatographic separations, providing reliable and precise measurements of a wide range of chemical compounds.

Automatically generated - may contain errors

2 protocols using agilent 1100 hplc dad

1

HPLC-DAD Analysis of Methoxyflavones

Check if the same lab product or an alternative is used in the 5 most similar protocols
An Agilent 1100 HPLC-DAD was used for the chromatographic analysis (Agilent Technologies, California, USA). On a Luna Omega Polar C18 column (5 μm, 100 Å, 4.6 mm × 250 mm) (Phenomenex Inc., Torrance, CA, USA), the separation runs were carried out at 40 °C. A mixture of aqueous acetic acid (0.1% v/v) and methanol (35:65) was used as a mobile phase. The injection volume was 20 μL, and the flow rate was 0.8 mL/min with isocratic elution. The detection UV wavelength was set at 254 nm.
The electrospun shellac fibers loaded with KP extract were successfully powdered. A 100 mg sample powder was precisely weighed into a 1.0 mL dry, clean volumetric flask. To aid in full solubility, the mobile phase was added and ultrasonically mixed. The same mobile phase was used to adjust the volume, and the analysis was performed using the 100 mg/mL sample solution. The validated method was then used to simultaneously measure the amounts of DMF, TMF, and PMF in various electrospun shellac fibers loaded with KP extract.
In the case of sample solutions obtained from an in vitro dissolution study of KP extract-loaded electrospun shellac fibers, each sample from the dissolution vessels was directly injected into the HPLC-DAD system, and the concentrations of methoxyflavones in each sample were calculated using their corresponding calibration curves.
+ Open protocol
+ Expand
2

HPLC-DAD Analysis of Rhein Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols
The Agilent 1100 HPLC–DAD (Agilent Technologies, CA, USA) was used for all analyses. All chromatographic conditions were carried out with isocratic elution utilizing a Luna Omega Polar C18 column (5 μm, 100 Å, 4.6 mm × 250 mm) (Phenomenex Inc., Torrance, CA, USA), a flow rate of 1 mL/min and a detection wavelength of 254 nm, with some changes as detailed in Table 4. By comparing the unknown substance’s retention time and UV spectrum to the standard, rhein was found.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?