The largest database of trusted experimental protocols

Ma2psb flow probe

Manufactured by Transonic Systems
Sourced in United States

The MA2PSB flow probe is a device designed to measure flow rate. It functions by utilizing ultrasonic technology to detect and quantify the movement of fluids through a specific area.

Automatically generated - may contain errors

3 protocols using ma2psb flow probe

1

Multimodal Physiological Monitoring in Animal Studies

Check if the same lab product or an alternative is used in the 5 most similar protocols
The arterial catheter was connected to a pressure transducer (BD DTX Plus Transducer, Becton Dickinson, Franklin Lakes, NJ; amplifier TA-100, CWE, Ardmore, PA) to monitor blood pressure.
Aortic blood flow was measured using MA2PSB flow probe (Transonic Systems Inc. Ithaca, NY) connected to the transit-time flowmeter (TS420, Transonic Systems Inc., Ithaca, NY).
Expiratory flow was measured using a pneumotachograph (1100 Series, Hans Rudolph, Inc. Shawnee, KS), as previously described.46 (link) Mixed expired O2 (FchO2), CO2 (FchO2), and H2S fractions (FchH2S) were measured continuously using O2 (Oxystar-100, CWE Inc. Ardmore, PA), CO2 (model 17630, VacuMed, Ventura, CA), and H2S (Interscan RM series; range: 0–200 ppm, Interscan Corporation, Simi Valley, CA) analyzers.
Electrocardiogram (ECG) was recorded by a bioelectric amplifier (Differential AC amplifier, Model 1700, A-M Systems, Sequim, WA).
All signals were digitized at 400 Hz using an analog-to-digital data acquisition system (Power Lab 16/35, AD Instruments, Inc. Colorado Springs, CO) and were visualized online. All data were stored for further analysis by LabChart7 (AD Instruments, Inc. Colorado Springs, CO).
+ Open protocol
+ Expand
2

Liver Microcirculation and Portal Flow

Check if the same lab product or an alternative is used in the 5 most similar protocols
Graft microcirculation and red blood cell velocity were measured using an O2C device with a corresponding surface probe (O2C-oxygen to see device, LF1 surface probe; LEA Medizintechnik GmbH, Giessen, Germany). Mean of the measurements from 4 standard points on the liver surface were used to characterize graft microcirculation.
Transit-time perivascular flowmeter was used for portal venous flow measurements (T403 device, MA2PSB flow probe; Transonic Systems, Inc., Ithaca, NY, USA). Portal venous pressure was measured using a monitoring device (Sirecust 404; Siemens, Erlangen, Germany) following direct puncture of the portal vein with a 27-gauge needle (BD Microlance 3; Becton Dickinson GmbH, Heidelberg, Germany).
+ Open protocol
+ Expand
3

Liver Graft Microcirculation Assessment

Check if the same lab product or an alternative is used in the 5 most similar protocols
Graft microcirculation and red blood cell velocity were measured using an O2C device with a corresponding surface probe (O2C-oxygen to see device, LF1 surface probe; LEA Medizintechnik GmbH, Giessen, Germany). Mean values of the measurements from four standard points on the liver surface were used to characterize graft microcirculation.
Transit-time perivascular flowmeter was used for portal venous flow measurements (T403 device, MA2PSB flow probe; Transonic Systems, Inc, Ithaca, NY).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!