Example 102
3-(3-((1-(4-Fluorobenzoyl)-4-hydroxypiperidin-4-yl)methyl)-4-oxo-3,4-dihydro)-7H-pyrrolo[2,3-d]pyrimidin-7-yl)benzonitrile (120 mg, 0.25 mmol), palladium on carbon (10% wt, 10 mg), Raney nickel (10 mg), lithium hydroxide (10 mg, 0.42 mmol) and methanol (10 mL) were added to a 25-mL pressure tank reactor (5 atm) fitted with a magnetic stir bar. The mixture was placed under a hydrogen atmosphere and stirred for 30 min at room temperature. The solids were removed by filtration and the filtrate was concentrated under reduced pressure. The residue was purified by preparative HPLC* to give 7-(3-(aminomethyl)phenyl)-3-((1-(4-fluorobenzoyl)-4-hydroxypiperidin-4-yl)methyl)-3,7-dihydro-4H-pyrrolo[2,3-d]pyrimidin-4-one (I-51, 26 mg, 21%). 1H NMR (400 MHz, DMSO-d6) δ 8.13 (s, 1H), 7.65 (s, 1H), 7.57-7.50 (m, 1H), 7.48-7.44 (m, 4H), 7.37-7.35 (m, 1H), 7.30-7.24 (m, 2H), 6.69 (d, 1H), 4.97 (s, 4.23-4.12 (m, 1H), 4.05 (s, 2H), 3.79 (s, 2H), 3.52-3.37 (m, 2H), 3.32-3.01 (m, 2H), 1.74-1.23 (m, 4H) ppm. LCMS: (ESI) m/z 476.30 [M+H]. *Column: Waters XBridge BEH Shield RP18 OBD Prep Column, 130 Å, 5 μm, 19 mm×150 mm. Mobile phase A: 10 mM aqueous ammonium bicarbonate/Mobile phase B: acetonitrile. Gradient: 7% B to 35% B over 10 min. Flow rate: 2.5 mL/min. Detector: 220 and 254 nm.
Method O