The largest database of trusted experimental protocols

Xbridge beh shield rp18 obd prep column

Manufactured by Waters Corporation

The XBridge BEH Shield RP18 OBD Prep Column is a reversed-phase liquid chromatography column designed for preparative-scale separations. It features a bonded C18 stationary phase and an ethylene-bridged hybrid (BEH) particle technology. The column is intended for use in preparative applications.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using xbridge beh shield rp18 obd prep column

1

Hydrogenation and HPLC Purification of Pyrrolo[2,3-d]pyrimidin-4-one

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 102

[Figure (not displayed)]

3-(3-((1-(4-Fluorobenzoyl)-4-hydroxypiperidin-4-yl)methyl)-4-oxo-3,4-dihydro)-7H-pyrrolo[2,3-d]pyrimidin-7-yl)benzonitrile (120 mg, 0.25 mmol), palladium on carbon (10% wt, 10 mg), Raney nickel (10 mg), lithium hydroxide (10 mg, 0.42 mmol) and methanol (10 mL) were added to a 25-mL pressure tank reactor (5 atm) fitted with a magnetic stir bar. The mixture was placed under a hydrogen atmosphere and stirred for 30 min at room temperature. The solids were removed by filtration and the filtrate was concentrated under reduced pressure. The residue was purified by preparative HPLC* to give 7-(3-(aminomethyl)phenyl)-3-((1-(4-fluorobenzoyl)-4-hydroxypiperidin-4-yl)methyl)-3,7-dihydro-4H-pyrrolo[2,3-d]pyrimidin-4-one (I-51, 26 mg, 21%). 1H NMR (400 MHz, DMSO-d6) δ 8.13 (s, 1H), 7.65 (s, 1H), 7.57-7.50 (m, 1H), 7.48-7.44 (m, 4H), 7.37-7.35 (m, 1H), 7.30-7.24 (m, 2H), 6.69 (d, 1H), 4.97 (s, 4.23-4.12 (m, 1H), 4.05 (s, 2H), 3.79 (s, 2H), 3.52-3.37 (m, 2H), 3.32-3.01 (m, 2H), 1.74-1.23 (m, 4H) ppm. LCMS: (ESI) m/z 476.30 [M+H]. *Column: Waters XBridge BEH Shield RP18 OBD Prep Column, 130 Å, 5 μm, 19 mm×150 mm. Mobile phase A: 10 mM aqueous ammonium bicarbonate/Mobile phase B: acetonitrile. Gradient: 7% B to 35% B over 10 min. Flow rate: 2.5 mL/min. Detector: 220 and 254 nm.

Method O

+ Open protocol
+ Expand
2

Synthesis and Characterization of Pyrrolo[2,3-d]pyrimidine Derivative

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 102

[Figure (not displayed)]

3-(3-((1-(4-Fluorobenzoyl)-4-hydroxypiperidin-4-yl)methyl)-4-oxo-3,4-dihydro-7H-pyrrolo[2,3-d]pyrimidin-7-yl)benzonitrile (120 mg, 0.25 mmol), palladium on carbon (10% wt, 10 mg), Raney nickel (10 mg), lithium hydroxide (10 mg, 0.42 mmol) and methanol (10 mL) were added to a 25-mL pressure tank reactor (5 atm) fitted with a magnetic stir bar. The mixture was placed under a hydrogen atmosphere and stirred for 30 min at room temperature. The solids were removed by filtration and the filtrate was concentrated under reduced pressure. The residue was purified by preparative HPLC* to give 7-(3-(aminomethyl)phenyl)-3-((1-(4-fluorobenzoyl)-4-hydroxypiperidin-4-yl)methyl)-3,7-dihydro-4H-pyrrolo[2,3-d]pyrimidin-4-one (I-51, 26 mg, 21%). 1H NMR (400 MHz, DMSO-d6) δ 8.13 (s, 1H), 7.65 (s, 1H), 7.57-7.50 (m, 1H), 7.48-7.44 (m, 4H), 7.37-7.35 (m, 1H), 7.30-7.24 (m, 2H), 6.69 (d, 1H), 4.97 (s, 1H), 4.23-4.12 (m, 1H), 4.05 (s, 2H), 3.79 (s, 2H), 3.52-3.37 (m, 2H), 3.32-3.01 (m, 2H), 1.74-1.23 (m, 4H) ppm. LCMS: (ESI) m/z 476.30 [M+H]. *Column: Waters XBridge BEH Shield RP18 OBD Prep Column, 130 Å, 5 μm, 19 mm×150 mm. Mobile phase A: 10 mM aqueous ammonium bicarbonate/Mobile phase B: acetonitrile. Gradient: 7% B to 35% B over 10 min. Flow rate: 25 mL/min. Detector: 220 and 254 nm.

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!