The largest database of trusted experimental protocols

Kinetex polar c18 column 100 a

Manufactured by Phenomenex
Sourced in United States

The Kinetex Polar C18 column 100 A is a high-performance liquid chromatography (HPLC) column designed for the separation and analysis of polar and non-polar compounds. It features a particle size of 2.6 μm and a pore size of 100 Å, which provides efficient and high-resolution separations.

Automatically generated - may contain errors

2 protocols using kinetex polar c18 column 100 a

1

Analytical Standards for Oxidative Stress

Check if the same lab product or an alternative is used in the 5 most similar protocols
The analytical reference standards of 8-oxoGua, 8-oxodGuo, and 8-oxoGuo were purchased from Spectra 2000 SRL (Rome, Italy). The isotope-labelled internal standards (13C15N2), 8-oxodGuo, and (13C15N2) 8-oxoGuo were obtained from C/D/N Isotopes Inc. (Pointe-Claire, QC, Canada). The (13C15N2) 8-oxoGua (98%) was obtained from Cambridge Isotope Laboratories Inc. (Tewksbury, MA, USA). The 3-NO2Tyr was purchased from Cayman Chemical Company (Ann Arbor, MI, USA) and 3-NO2Tyr d3 from Toronto Research Chemicals (Toronto, ON, Canada). The 5-MeCyt was obtained from Sigma Aldrich SRL (Milano, Italy) and Cotinine d3 from CDN Isotopes Inc. (Pointe-Claire, QC, Canada). Glacial acetic acid 30% NH3, dimethyl sulfoxide, sodium hydroxide solution (50–52% in water) and CHROMASOLV® gradient grade 99.9% methanol and acetonitrile for HPLC/MS 99.9% carbon disulfide low benzene content were obtained from Sigma Aldrich (Saint Louis, MO, USA). Purified water was obtained from a Milli-Q Plus system (Millipore, Milford, MA, USA). Anotop 10LC syringe filter devices (0.2 m pore size, 10 mm diameter) were purchased from Whatman Inc. (Maidstone, UK). The Kinetex Polar C18 column 100 A (150 × 4.6 mm, 2.6 m), supplied by Phenomenex (Torrance, CA, USA), was used throughout the study.
+ Open protocol
+ Expand
2

Quantification of Oxidized Guanine Biomarkers

Check if the same lab product or an alternative is used in the 5 most similar protocols
The analytical reference standards of 8-oxoGua. 8-oxodGuo and 8-oxoGuo were purchased by Spectra 2000 s.r.l (Rome, Italy). The isotope labeled internal standards (13C15N2) 8-oxodGuo and (13C15N2) 8-oxoGuo were obtained from CDN Isotopes Inc. (Pointe-Claire, QC, Canada). (13C15N) 8-oxoGua (98%) was obtained from Cambridge Isotope Laboratories Inc. (Tewksbury, MA, USA).
Glacial acetic acid 30% NH3. Dimethyl sulfoxide. Sodium hydroxide solution (50%–52% in water) and CHROMASOLV® gradient grade ≥99.9% Methanol and Acetonitrile for HPLC/MS ≥99.9% carbon disulfide low benzene content were obtained from Sigma Aldrich (Saint Louis, MO, USA). Purified water was obtained from a Milli-Q Plus system (Millipore Milford, MA, USA). Anotop 10LC syringe filter device (0.2 µm pore size, 10 mm diameter) were purchased from Whatman Inc. (Maidstone, UK). A Kinetex Polar C18 column 100 A. (150 × 4.6 mm, 2.6 µm) supplied by Phenomenex (Torrance, CA, USA) were used throughout the study.
The urine samples were analyzed on a Series 200 LC quaternary pump (PerkinElmer, Norwalk, CT, USA) coupled with an AB/Sciex API 4000 triple-quadrupole mass spectrometry detector equipped with a Turbo Ion Spray (TIS) probe.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!