The largest database of trusted experimental protocols

Human madcam 1 duoset elisa kit

Manufactured by R&D Systems
Sourced in United States

The Human MAdCAM-1 DuoSet ELISA kit is a laboratory tool used to quantify levels of the mucosal addressin cell adhesion molecule-1 (MAdCAM-1) protein in human samples. It is a reagent system designed to measure the concentration of the target analyte through an enzyme-linked immunosorbent assay (ELISA) format.

Automatically generated - may contain errors

3 protocols using human madcam 1 duoset elisa kit

1

Quantification of Serum MAdCAM-1 and TGF-β1

Check if the same lab product or an alternative is used in the 5 most similar protocols
Two milliliter Blood was collected in SST II Advance BD Vacutainer (RWF 367956). Serum was aliquoted and stored at −80°C for batch analysis. Human MAdCAM-1 DuoSet ELISA kit (R&D Systems-DY6056-05) was used for estimation of soluble MAdCAM-1 in serum in accordance with manufacturer's protocol. Human/Mouse TGF beta 1 Uncoated ELISA kit (Invitrogen) was used for quantification of total TGF-β1 in serum. Serum was diluted 1:5 in Phosphate buffered saline and treated with 1N HCl to activate latent TGF-β1. Following 10 min incubation at room temperature, the reaction was neutralized using 1N NaOH and TGF-β1 was estimated in accordance with manufacturer's protocol.
+ Open protocol
+ Expand
2

Quantifying soluble MAdCAM-1 in plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Human MAdCAM-1 DuoSet ELISA kit (R&D Systems-DY6056-05, Minneapolis, USA) was used for estimation of soluble MAdCAM-1 in plasma in accordance with the manufacturer’s protocol. Briefly, wells coated with capture antibody and reagent diluent (1% BSA in PBS) were added for blocking. MAdCAM standard or 1:100 diluted plasma was added to wells and incubated overnight at 4°C. Incubation with detection antibody was followed by addition of streptavidin-HRP which was allowed to react with a substrate solution to give chromogenic readout. Reaction was stopped using 2N H2SO4, and absorbance was measured at 450 and 570 nm using Synergy H1 microplate reader (Biotek, Vermont, USA). Readings at 570 nm were subtracted from 450 nm and used to plot the standard curve. Plasma concentration of sMAdCAM was calculated by interpolating absorbance values and multiplying by dilution factor.
+ Open protocol
+ Expand
3

Quantification of Plasma Biomarkers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma IL-15, sMAdCAM-1 and LPS levels were quantified using Human IL-15 DuoSet ELISA kit (R&D Systems), Human MAdCAM-1 DuoSet ELISA kit (R&D Systems) and Human Lipopolysaccharides ELISA kit (MyBioSource) respectively, following manufacturers' recommendations. The values below the level of detection were assigned as zero.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!