The largest database of trusted experimental protocols

Echospeed plus

Manufactured by GE Healthcare
Sourced in United States

Echospeed Plus is a compact and portable ultrasound system designed for clinical use. It provides real-time imaging capabilities for various diagnostic applications.

Automatically generated - may contain errors

2 protocols using echospeed plus

1

Dynamic Breast MRI Contrast Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI examinations were performed with a 1.5‐T MR scanner using a dedicated four‐channel phased array breast coil (Echospeed Plus with EXCITE II, GE Medical Systems, Milwaukee, USA). MRI protocols included a sagittal, 3D Vibrant SPGR sequence for dynamic imaging (TR = 6.4 ms, TE = 3.0 ms, TI = 7.0 ms, flip angle = 10°, slice thickness = 4 mm without any interslice gap, matrix size = 256 × 256, field of view = 20–22 cm, NEX = 1, ZIP2, and scan time per acquisition = 68 seconds); and an axial, fat‐suppressed, T1‐weighted pulse sequence with enhancement. The Vibrant sequence was continuously repeated six times, with one phase before and five phases after contrast enhancement for dynamic acquisition. The contrast agent (Gd‐DTPA) was injected into the antecubital vein by a power injector at a rate of 2.0 mL/second based on patient body mass (0.2 mmol/kg), followed by a saline flush. An initial fat‐saturated T1‐weighted precontrast scan was first collected. A first postcontrast scan was collected two minutes after contrast agent injection. Four subsequent postcontrast images were acquired at intervals of 90 seconds, resulting in five postcontrast images for each patient (t = 2, 3.5, 5, 6.5, and 8 minutes).
+ Open protocol
+ Expand
2

Hippocampal Volume Measurement using 3T MRI

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI Scans were performed on a 3.0T EXCITE HD MR imaging system (Echo-speed plus, General Electric, Milwaukee, WI, USA) with an 8NVHEAD-A coil using a three- dimensional, spoiled gradient recalled echo 3D-SPGR-T1 weighted sequence using the following parameters: repetition time (TR) = 7.7 ms; echo time = 1.6 ms; flip angle = 15′; number of excitations = 1; section thickness = 0.5 mm; field of view = 240 × 240 mm; and matrix size = 256 × 256 mm. The voxel size was 1 × 1 × 1 mm. The voxel-based morphometry was used to analyze the hippocampal volume, with the Biological Parametric Mapping (WFU PickAtlas Tool, http://fmri.wfubmc.edu/) and the MATLAB platform (version 7.0, Mathworks Inc. Sherbom, MA, USA) was used to calculate the hippocampal structure volume.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!