The largest database of trusted experimental protocols

Magnetom tim trio 3 t mri scanner

Manufactured by Siemens
Sourced in Germany

The MAGNETOM® Tim Trio 3 T MRI scanner is a magnetic resonance imaging system produced by Siemens. It operates at a magnetic field strength of 3 tesla and is designed to acquire high-quality medical images for diagnostic purposes.

Automatically generated - may contain errors

3 protocols using magnetom tim trio 3 t mri scanner

1

High-resolution structural and DTI brain imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
All scans were acquired on a Siemens MAGNETOM® Tim Trio 3 T MRI scanner using a 32-channel head coil (Erlangen, Germany). Using a T1-weighted 3D magnetization-prepared rapid gradient-echo (MPRAGE) imaging sequence, high-resolution whole brain anatomical images were obtained sagittally with the following parameters: TR = 1900 ms, TE = 2.52 ms, 1 mm3.
isotropic voxels, imaging matrix = 256 × 256, FOV = 256 mm, flip angle = 9°, and number of slices = 192. A diffusion-weighted echoplanar imaging sequence was used to obtain whole brain DTI data in 64 diffusion directions, including a single reference volume (b0 = 0 s/mm2), with the following parameters: TR = 6900 ms, TE = 86 ms, 1.5 × 1.5 × 2.0 mm voxels, imaging matrix = 128 × 128, FOV = 192 mm, parallel imaging (GRAPPA with acceleration factor of 3), b = 1000 s/mm2, and number of contiguous slices = 56.
+ Open protocol
+ Expand
2

PET Neuroimaging with MRI-Integrated Scanner

Check if the same lab product or an alternative is used in the 5 most similar protocols
The PET data were acquired on a prototype MR-compatible brain PET scanner (“BrainPET”) designed to fit inside the Magnetom Tim Trio 3T MRI scanner (Siemens Healthcare, Erlangen, Germany). Structural T1 images were acquired prior to radiotracer injection. Dynamic PET acquisition started concurrently with an injected IV bolus of 11C-PBR28, and data were stored in listmode format. T1 images were used for the generation of attenuation correction maps19 (link) as well as anatomical localization and spatial normalization of the PET data.
+ Open protocol
+ Expand
3

High-Resolution T1-Weighted MRI Acquisition

Check if the same lab product or an alternative is used in the 5 most similar protocols
This research followed the Declaration of Helsinki doctrine and was approved by the Research Ethics Boards of both The Hospital for Sick Children and York University. Informed consent was obtained from all participants prior to testing and after explanation of the nature and possible consequences of the study.
A high resolution, T1 weighted three-dimensional MPRAGE anatomical image was obtained for all participants using a Siemens MAGNETOM Tim Trio 3 T MRI scanner with a 32-channel head coil at the Sherman Health Sciences Research Centre at York University (Toronto, Canada). A scan of the entire head was acquired sagittally with the following parameters: rapid gradient echo, 1 mm3 isotropic voxels, TR = 1900 ms, TE = 2.52 ms, 256 × 256 matrix, and flip angle = 9°.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists