Gel 60 tlc aluminum plate

Manufactured by Merck Group
Sourced in Germany

The Gel-60 TLC aluminum plate is a thin-layer chromatography (TLC) plate made of aluminum substrate with a silica gel 60 adsorbent layer. It is designed for qualitative and semi-quantitative analysis of various compounds through chromatographic separation.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using gel 60 tlc aluminum plate

1

Carbon Source Degradation Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The carbon source degradation products were detected by thin-layer chromatography (TLC) analysis. Briefly, samples (0.2 mL) were loaded onto a pre-coated silica gel-60 TLC aluminum plate (Merck, Darmstadt, Germany). After being developed with a solvent system consisting of formic acid/n-butanol/water (6:4:1, v:v:v), the plate was soaked in orcinol reagent (Sigma-Aldrich Co., LLC., St. Louis, MO, USA) and visualized at 120 °C for 1 min [8 (link)]. The scanned TLC profiles were analyzed by Quantity One (BioRad, Hercules, CA, USA) and the amounts of carbon source in each sample were quantified. Degradation rates were calculated as the percentage of total amounts at 0 h subtracted from those at 24 h after fermentation.
+ Open protocol
+ Expand
2

TLC Analysis of Carbohydrate Degradation

Check if the same lab product or an alternative is used in the 5 most similar protocols
To perform TLC, 0.2 μL of each sample was loaded on a pre-coated silica gel-60 TLC aluminum plate (Merck, Germany). After development with a solvent system consisting of formic acid, n-butanol, and water (6:4:1, v:v:v), the plate was soaked in orcinol reagent, and carbohydrates were visualized by heating at 120 C for 3 min.
To calculate the degradation rates of these carbohydrates, IntDen of each dot at the spot site was measured using ImageJ software (https://imagej.nih.gov/ij; National Institutes of Health, Bethesda, MD, USA). Then the degradation rates were calculated by comparing to control (0 h).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!