The largest database of trusted experimental protocols

Acquity lct premier xe

Manufactured by Waters Corporation

The Acquity LCT Premier XE is a high-performance liquid chromatography (HPLC) system designed for analytical and preparative applications. It features a mass spectrometry (MS) detector that enables the identification and quantification of compounds. The system is capable of delivering precise and reproducible results, making it a valuable tool for researchers and analysts in various industries.

Automatically generated - may contain errors

2 protocols using acquity lct premier xe

1

Enzymatic Activity Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fmoc (fluorenylmethyloxycarbonyl)-protected amino acids were purchased from Chem Impex. ChymoTrypsin (64.8 units/mg) was purchased from Sigma Aldrich. Trypsin (225 units/mg), papain (30.3 units/mg), and caspases 3 (100 units/µL) and 8 (0.2 mg/mL) were purchased from Fisher Scientific. All other chemicals were purchased from Sigma Aldrich. 1H NMR and 13C NMR spectra were obtained on an Avance DRX 400 MHz instrument. ESI mass spectra were obtained using a Waters Acquity LCT Premier XE. Assay measurements were carried out on a Bio-Tek ELx 800 Microplate Reader.
+ Open protocol
+ Expand
2

Comprehensive Biophysical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra were obtained on Bruker AV 500 and AV 600 MHz spectrometers with a relaxation delay of 4 seconds for both proton and carbon experiments. Infrared absorption spectra were obtained using a PerkinElmer FT-IR equipped with an attenuated total reflectance (ATR) accessory. High-resolution mass spectra were obtained for small molecules using a Waters Acquity LCT Premier XE equipped with an autosampler and direct injection port. High-resolution mass spectra and peptide mapping were acquired using a Thermo Q Exactive Plus Orbitrap Mass Spectrometer equipped with a direct injection port and switchable UltiMate 3000 nanoLC. Peptide masses were analyzed using Thermo-Fisher Proteome Discoverer software version 1.4. SDS-PAGE was performed using Bio-Rad Any kD Mini-PROTEAN-TGX gels and gels were stained with Coomassie for visualization of protein or 0.1 N iodine for visualization of PEG. SDS-PAGE protein standards were obtained from Bio-Rad (Precision Plus Protein Pre-stained Standards).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!