The largest database of trusted experimental protocols

10 mhz transducer

Manufactured by GE Healthcare
Sourced in United States

The 10-MHz transducer is a compact and versatile ultrasound probe used for various medical imaging applications. It operates at a frequency of 10 megahertz and is designed to provide high-resolution imaging of targeted anatomical structures.

Automatically generated - may contain errors

3 protocols using 10 mhz transducer

1

Carotid Intima-Media Thickness and Arterial Stiffness Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Measurements of common CIMT by ultrasonography of the right common carotid artery was carried out using an Ethiroli Tiny‐16a (Surabi Biomedical Instrumentation, Coimbatore, India) in APCAPS, and LOGIQ Book XP with a 10‐MHz transducer (GE Healthcare, Milwaukee, WI, USA) in NaIS. The protocol used has been described in detail elsewhere.13, 15 The mean CIMT was calculated as the mean of right CIMT measurements with carotid plaque excluded. Although AtheroEdge Software in the original APCAPS study and Intima Scope Software (Cross Media, Tokyo, Japan) were used to measure mean CIMT, we re‐evaluated the mean CIMT of APCAPS participants using Intima Scope to avoid the systematic difference of CIMT in the two different types of software.16 Arterial stiffness was evaluated as PWV by the Vicorder system (Skidmore Medical Limited, Bristol, UK) in APCAPS, and cardio‐ankle vascular index (CAVI) by the VaSera system (Fukuda Denshi, Tokyo, Japan) in NaIS.
+ Open protocol
+ Expand
2

Carotid Intima-Media Thickness Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Measurement of CIMT by ultrasonography of the left and right carotid arteries was performed by two medical doctors (NT and MN) using a LOGIQ Book XP with a 10-MHz transducer (GE Healthcare, Milwaukee, WI, USA) that was programmed with the IMT measurement software Intimascope (Cross Media Ltd., Tokyo, Japan) [13 (link)]. The protocol that was used has been described in detail elsewhere [14 (link)]. The values for right and left CIMT without plaque measurement were calculated, and the higher CIMT value was used for the analysis. Based on previous studies [8 (link),15 (link),16 (link)], we defined carotid atherosclerosis as a CIMT ≥1.1 mm. Intra-observer variation agreement for CIMT (NT, n = 32) was 0.91 (P value (P) <0.01), and inter-observer variation agreement (NT vs. MN, n = 41) was 0.78 (P < 0.01).
+ Open protocol
+ Expand
3

Thyroid Cysts and Autoantibody Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
A trained interviewer obtained information on clinical characteristics. Bodyweight and height were measured with an automatic body composition analyzer (BF-220; Tanita, Tokyo, Japan) and BMI (kg/m2) was calculated. Systolic blood pressure (SBP) was recorded at rest.
A fasting blood sample was collected. TSH, free T3, free T4, and TPO-Ab were measured by standard procedures at the LSI Medience Corporation (Tokyo, Japan). HbA1c, triglycerides (TG), and high-density lipoprotein cholesterol (HDLc) were also measured using standard procedures at SRL, Inc. (Tokyo, Japan).
Detecting thyroid cysts are identified by experienced technicians using a LOGIQ Book XP with a 10-MHz transducer (GE Healthcare, Milwaukee, WI, USA). A thyroid cyst (maximum diameter ≥ 2.0 mm) without a solid component was defined as a thyroid cyst for this study. The positive status of TPO-Ab (+) was defined at and above 16 IU/mL.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!