The largest database of trusted experimental protocols

2 protocols using anti mcherry 1c51

1

Quantitative Immunoblotting of Cellular Markers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Membranes were decorated using anti‐mCherry‐1C51 (Abcam), anti‐HA.11‐16B12 (BioLegend), anti‐G6PDH (Sigma‐Aldrich), anti‐Tubulin (clone B5‐1‐2, Sigma‐Aldrich), anti‐WIPI1 (W2394 Sigma‐Aldrich), anti‐Tubulin (T9026 Sigma‐Aldrich) anti‐Vps35 (ab10099 Abcam, ab157220 Abcam) and anti‐Vps26 (ab181352 Abcam). After incubation with the primary antibody, signals were detected by secondary antibodies coupled to infrared dyes (LICOR), IRDye® 800CW goat anti‐mouse IgG, IRDye® 800CW goat anti‐rabbit IgG, IRDye® 680LT goat anti‐rabbit IgG, IRDye 800CW goat anti‐rat IgG, IRDye® 680RD donkey anti‐rabbit IgG, and detected on a LICOR Odyssey Infrared Imager. Band intensity was quantified using Odyssey software with background removal activated.
+ Open protocol
+ Expand
2

Immunoprecipitation and SDS-PAGE Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lysates and eluates from Immunoprecipitations were run on 10% acrylamide gels for SDS–PAGE, freshly prepared and used the same day: 10% Protogel (30% w/v acrylamide, 0.8% bis‐acrylamide (37.5:1 solution, National diagnostics, Atlanta, USA), 380 mM Tris–HCl pH 8.8, 0.1% w/v SDS (Applichem, Darmstadt, Germany), 0.06% v/v TEMED (Applichem), 0.06% w/v APS (Applichem) for the running gel and 5% Protogel, 165 mM Tris–HCl pH 6.8, 0.1% w/v SDS, 0.08% v/v TEMED, 0.04% w/v APS for the stacking gel. Running buffer for SDS–PAGE was 190 mM glycine (Applichem), 25 mM Tris‐base (Applichem), 0.5% SDS. To facilitate Atg18 migration and avoid formation of aggregates, samples were reduced and denatured at 90°C using NuPAGE buffer (Thermo Fisher) containing LDS instead of SDS and supplemented with 100 mM DTT. Gels were blotted on 0.45 µm nitrocellulose membrane (Amersham) overnight at a constant current of 200 mA using a Trans‐Blot® Cell (Bio‐Rad, USA). Membranes were decorated using anti‐mCherry‐1C51 (Abcam), anti‐HA.11‐16B12 (BioLegend), anti‐G6PDH (Sigma‐Aldrich), anti‐Tubulin (clone B5‐1‐2, Sigma‐Aldrich), and anti‐WIPI1 (C‐terminal epitope, Sigma‐Aldrich).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!