Triple quadrupole lc ms ms 6410 system

Manufactured by Agilent Technologies
Sourced in United States

The Agilent 6410 Triple Quadrupole LC-MS/MS system is a high-performance liquid chromatography-tandem mass spectrometry instrument. It is designed for sensitive and selective quantitation of target analytes in complex matrices.

Automatically generated - may contain errors

2 protocols using triple quadrupole lc ms ms 6410 system

1

Rice Metabolite Profiling via LC-MS/MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Metabolites were extracted from rice cells (40 mg) or rice leaves (80–100 mg) and measured on a triple quadrupole LC-MS/MS 6410 system (Agilent Technologies, Santa Clara, CA, USA) equipped with a Zorbax SB-C18 column (50 × 2.1 mm ID, 1.8 μm, Agilent Technologies) as described previously23 (link). Amount of each metabolite was estimated using synthetic standards (CoP, FP) or purified chemicals momilactone A (MoA) and momilactone B (MoB).
+ Open protocol
+ Expand
2

Quantification of N-linolenoyl-L-Gln in OS isolates

Check if the same lab product or an alternative is used in the 5 most similar protocols
The OS isolates were centrifuged and diluted 100-fold before applying 10 μL on a triple quadrupole LC-MS/MS 6410 system (Agilent Technologies, Santa Clara, CA, USA) equipped with a Zorbax SB-C18 column [50 × 2.1 mm ID, 1.8 μm, Agilent Technologies]. MS was set to operate in negative electrospray ionization (ESI) mode and mass scan data were collected in m/z 150–1000 range. Sample separation was achieved with solvent A [0.1% (v/v) formic acid in water] and solvent B [0.1% (v/v) formic acid in acetonitrile] in time (min)/B (%) gradient program: 0/5, 0.5/5, 2/40, 6/40, 10/95, 15/95, 16/5, 20/5. Constant flow rate of 0.4 mL/min was applied to chromatographic column placed in thermostatic chamber controlled at 40 °C. Additional MS variable parameters were used as follows: fragmentor 135V, dwell 200, and 7V cell accelerator voltage. Synthetic FAC (N-linolenoyl-L-Gln) was used to estimate FAC content in individual OS isolates, which was then expressed as N-linolenoyl-L-Gln equivalents.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!