The largest database of trusted experimental protocols

Whatman grade 1 chr chromatography paper

Manufactured by GE Healthcare

Whatman Grade 1 CHR chromatography paper is a type of laboratory filter paper designed for use in chromatography applications. It is a cellulose-based material with a consistent pore structure and high absorptive capacity, making it suitable for separating and analyzing various substances through chromatographic techniques.

Automatically generated - may contain errors

2 protocols using whatman grade 1 chr chromatography paper

1

Glucose Oxidase Activity Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Glucose oxidase (GOx) from Aspergillus niger, HRP, D-(+)- glucose, sodium acetate anhydrate, sodium phosphate monobasic, and acetic acid were purchased from Sigma Aldrich Co. (Saint, Louis, MO). Sodium phosphate dibasic and KI were purchased from Fischer Scientific Co. (Hampton, NH). Whatman Grade 1 CHR chromatography paper was purchased from GE Healthcare Life Sciences (Pittsburgh, PA).
+ Open protocol
+ Expand
2

Colorimetric Assay for Glucose Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Glucose oxidase (GOx) from Asperillus niger was a gift from Fitzgerald Industries International (Acton, MA). D-(+)-glucose, acetylcholinesterase (AChE) from Electrophorous electricus (electric eel) (14.6 mg solid, 137 U/mg), acetylthiocholine iodide (ATC), 5,5′-dithiobis(2-nitrobenzoic acid) (DTNB), and sodium phosphate monobasic were purchased from Sigma Aldrich Co. (St. Louis, MO). Sodium phosphate dibasic and KI were purchased from Fischer Scientific Co. (Hampton, NH). Whatman Grade 1 CHR chromatography paper was purchased from GE Healthcare Life Sciences (Pittsburgh, PA).
PBS buffer (0.1 M, pH 6.0) was prepared by addition of 87.7 mL of sodium phosphate monobasic (0.2 M) and 12.3 mL of sodium phosphate dibasic (0.2 M). GOx (120 U/mL) was prepared with phosphate-buffered saline (PBS) (pH 6.0). A HRP solution was prepared with PBS at 30 U/mL. KI (1.0 M) was prepared with DI water. Various concentrations of glucose were made in DI water (0.5, 1 -4 mM). DTNB (5 mg/mL), various concentrations of ATC (0, 0.5, 1 -14 mM) and AChE (0.18 U/mL) were prepared in PBS buffer (pH 6.0). A solution of AChE:DTNB (1:1) was prepared fresh prior to the ATC assays.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!