The largest database of trusted experimental protocols

Eurostar power b

Manufactured by IKA Group

The Eurostar Power-B is a laboratory stirrer from IKA Group. It features electronic speed control and a digital display to monitor the stirring speed.

Automatically generated - may contain errors

2 protocols using eurostar power b

1

Quantifying Brain Radioactivity

Check if the same lab product or an alternative is used in the 5 most similar protocols
The whole brains were thawed and homogenized in 2.5 mL 50 mM Tris HCl buffer (pH 7.4) with 0.5% Triton, using a glass Teflon homogenizer (15 strokes, 900 rpm; Eurostar Power-B, IKA-Werke). Duplicates of 100 and 250 µl were transferred to glass scintillation vials (Perkin Elmer, 20 mL) and 15 mL Hionic-Fluor (Perkin Elmer) was added. The samples were shaken for 60 s and stored in darkness for 30 min before radioactivity was counted in a liquid scintillation analyzer (Tri-Carb 2810TR; PerkinElmer). Brain radioactivity was expressed as the percentage of the total injected radioactivity left in the brain.
+ Open protocol
+ Expand
2

Synthesis and Characterization of ALPCs

Check if the same lab product or an alternative is used in the 5 most similar protocols
To
previously synthesized LGPCs (1 mol), a phase transfer catalyst (tetrabutylammonium
hydrogen sulfate, TBAHS; tetrabutylammonium bromide, TBAB; tetrabutylammonium
iodide, TBAI; cetyltrimethylammonium bromide, CTAB; methyltriphenylphosphonium
bromide, MTPB; phenyltrimethylammonium tribromide, PTMTB; or tetrabutylphosphonium
bromide, TBPB) (0.003 mol), NaOH (1.5 mol), and the respective alkyl
bromide (1-bromododecane, 1-bromotetradecane, 1-bromohexadecane, or
1-bromooctadecane) were carefully added to a glass reactor with five
joints of 24 × 40N. The solid mixture was heated
at 100 °C under constant agitation with the aid of a mechanical
stirrer Eurostar Powerb IKAWERKE. After 72 h and reaction completion
(follow-up through TLC analysis), the final mixture was washed three
times with brine solution. Product (ALPC) liquid–liquid extraction
was performed with hexane. Excess water was then removed through Na2SO4 addition followed by the salt filtration. Finally,
the exceeding solvent removal was later performed in vacuo. The major ALPC [1-O-dodecyl-2-O-acyl-sn-glycero-3-phosphocholine (ALPC12), 1-O-tetradecyl-2-O-acyl-sn-glycero-3-phosphocholine (ALPC14), 1-O-hexadecyl-2-O-acyl-sn-glycero-3-phosphocholine (ALPC16),
and 1-O-octadecyl-2-O-acyl-sn-glycero-3-phosphocholine (ALPC18)] product yields are
summarized in Table 3.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!