Hematological Analysis of Heparinized Blood

Check if the same lab product or an alternative is used in the 5 most similar protocols
The heparinized blood samples were analyzed regarding number of Red Blood Cells (RBCs), White Blood Cells (WBCs), Hemoglobin concentration (Hb), Hematocrit (HCT), and differential count of polymorphs and lymphocytes according to standard methods using an Animal Blood Counter-ABC vet (Horiba ABX, France)38 ,39 (38, 39)37 ,38 (38, 39).
+ Open protocol
+ Expand
2

Comprehensive Assessment of Biological Parameters

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood and tissue samples from groups A, G &H were assessed for biochemical, hematological and histopathological changes. Biochemical profiles of heart, kidney, and liver functions were assessed by measuring the serum aspartate aminotransferase (AST), alanine aminotransferase (ALT), albumin, bilirubin, total protein, creatine kinase (CK-MB), lactate dehydrogenase (LDH), creatinine and blood urea. All tests were performed according to the standard methods (Scott et al., 2012 (link)). Hematological parameters; hemoglobin, hematocrit (HCT), red blood cells (RBC), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), white blood cell (WBC), granulocyte count and lymphocytes were determined using Animal Blood Counter-ABC vet (Horiba ABX, France).
For histopathological studies, at autopsy, one gram from liver, heart, lung, kidney, and spleen was fixed in 10% formaldehyde; dehydrated through ascending grades of alcohol, cleared in xylene, wax-impregnated and embedded in paraffin wax. They were sectioned using microtome (Leica RM 2125, Leica Biosystems Nussloch GmbH, Germany) and stained with haematoxylin and Eosin and examined for histopathological changes using light microscope (Olympus BH-2, Olympus, Tokyo, Japan) (Fowotade et al., 2017 (link)).
+ Open protocol
+ Expand
3

Comprehensive Blood Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The heparinized blood samples were analyzed for the number of red blood cells (RBCs), white blood cells (WBCs), and platelets, hemoglobin concentration (Hb%), hematocrit value (HTC), packed cells volume (PCV), mean corpuscle volume (MCV), mean corpuscle hemoglobin (MCH), mean corpuscle hemoglobin concentration (MCHC) and the differential count of polymorphs and lymphocytes according to standard methods using an Animal Blood Counter-ABC vet (Horiba ABX, France).
+ Open protocol
+ Expand
4

Analytical techniques for 5-FU study

Check if the same lab product or an alternative is used in the 5 most similar protocols
5-Fluorouracil (5-FU), Triton X-100, Tween 80, and cyclophosphamide were purchased from Sigma-Aldrich (St. Louis, MO, USA). Dimethylsulfoxide (DMSO) was purchased from Mallinckrodt Chemicals (Phillipsburg, NJ, USA). Kits for biochemical analysis were purchased from Labtest (Lagoa Santa, MG, Brazil). An automatic biochemical analyzer (COBAS Mira Plus, Roche Diagnostic Systems) and an automatic hematological analyzer (Animal Blood Counter -ABC Vet, Horiba) were used.
+ Open protocol
+ Expand
5

Comprehensive Hematological and Biochemical Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
After blood samples were collected into EDTA tubes, the following hematological parameters were analyzed using a Vet abc™ Animal Blood Counter (Horiba ABX, Montpellier, France): white blood cell (WBC), red blood cell (RBC), hemoglobin (HGB), hematocrit (HCT), platelet (PLT), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), and differential WBC (neutrophils, eosinophils, basophils, lymphocytes, and monocytes). The following serum biochemistry parameters were also measured using serum immediately separated from whole blood samples collected into tubes without anticoagulant with an automatic chemistry analyzer (Hitachi 7070, Hitachi, Tokyo, Japan): blood urea nitrogen (BUN), total cholesterol (TC), total bilirubin (TB), total protein (TP), albumin, alkaline phosphatase (ALP), aspartate transaminase (AST), alanine transaminase (ALT), creatinine, and triglyceride (TG).
+ Open protocol
+ Expand
6

Blood Count and Nitric Oxide Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood was collected in citrate (1:10). Blood count was quantified with a Vet abc animal blood counter (Horiba Medical; Grabels, France), while plasma NO2 and NO3 concentrations were measured with an ENO-20 NOx Analyzer (Eicom Corp., Kyoto, Japan).
+ Open protocol
+ Expand
7

Whole Blood Hematology Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Whole blood samples were analyzed with an automatic Vet abc™ Animal Blood Counter (Horiba ABX, Montpellier, France) using the hematology kits specified for that instrument (Horiba ABX, France) according to the manufacturer’s instructions.
+ Open protocol
+ Expand
8

Isoflurane Anesthesia and Blood Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
After six weeks, the mice were subjected to anesthesia by putting them in an anesthesia drop-chamber. Inside the chamber, a cotton gauze that was previously soaked with 2 mL of 20% isoflurane in propylene glycol was present. After that, cervical dislocation was done, and blood samples were collected from all animals, and plasma was separated. For cell blood count (CBC), heparinized blood samples were analyzed using Vet abc™ Animal Blood Counter (Horiba ABX, Montpellier, France). For glucose, cholesterol, triglycerides, and low-density lipoprotein (LDL) estimation; Reflotron®® plus was utilized using 30-µL plasma samples being put in specific device strips.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!