The largest database of trusted experimental protocols

Avanto tim 1.5t mri scanner

Manufactured by Siemens
Sourced in Germany

The Avanto Tim 1.5T MRI scanner is a magnetic resonance imaging (MRI) system manufactured by Siemens. It operates at a magnetic field strength of 1.5 Tesla and is designed to acquire high-quality images of the human body for diagnostic purposes.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using avanto tim 1.5t mri scanner

1

Multimodal Brain Imaging Protocol for Neurological Research

Check if the same lab product or an alternative is used in the 5 most similar protocols
Images were acquired on a Siemens Magnetom Avanto Tim 1.5T MRI scanner (Erlangen, Germany). The protocol included a T1-weighted 3-dimensional magnetization-prepared rapid gradient-echo image (repetition time [TR] 2,250 milliseconds, echo time [TE] 2.95 milliseconds, inversion time [TI] 850 milliseconds, flip angle 15°, voxel size 1.0 mm isotropic), a fluid-attenuated inversion recovery (FLAIR) sequence (TR 14,240 milliseconds, TE 89 milliseconds, TI 2,200 milliseconds, voxel size 1.2 × 1.0 × 2.5 mm, interslice gap 0.5 mm), and a diffusion-weighted echo-planar imaging (EPI) sequence (TR 10,200 milliseconds, TE 95 milliseconds, voxel size 2.5 mm isotropic; 7 scans with b = 0 s/mm2, 61 scans with b = 900 s/mm2).
+ Open protocol
+ Expand
2

Multimodal MRI Acquisition Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Imaging data was acquired on a Siemens Magnetom Avanto Tim 1.5 T MRI scanner (Erlangen, Germany). The protocol included a three-dimensional T1-weighted magnetization-prepared rapid gradient-echo (MPRAGE) sequence (repetition time (TR) = 2250 ms, echo time (TE) = 2.95 ms, inversion time (TI) = 850 ms, flip angle = 15°, voxel size = 1.0 mm isotropic), a fluid-attenuated inversion recovery (FLAIR) sequence (TR/TE/TI = 14240/89/2200 ms, voxel size = 1.2 × 1.0 × 2.5 mm, interslice gap = 0.5 mm), a diffusion-weighted imaging (DWI) sequence (TR/TE = 10200/95 ms, voxel size = 2.5 mm isotropic; 7 scans with b = 0 s/mm2, 61 scans with b = 900 s/mm2), and an eyes-closed resting-state T2*-weighted gradient-echo sequence (TR = 2400 ms, TE = 40 ms, voxel size = 3.5 × 3.5 × 4.0 mm, flip angle = 90°, fat saturated, interleaved ascending acquisition).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!