Synapt g2s quadrupole ion mobility separation time of flight q ims tof mass spectrometer

Manufactured by Waters Corporation
Sourced in United Kingdom

The Synapt G2S is a high-performance quadrupole-ion mobility separation-time-of-flight (Q-IMS-TOF) mass spectrometer designed for advanced analytical applications. It combines the capabilities of quadrupole, ion mobility separation, and time-of-flight mass analyzer technologies to provide high-resolution, accurate mass measurements and enhanced separation of complex samples.

Automatically generated - may contain errors

2 protocols using synapt g2s quadrupole ion mobility separation time of flight q ims tof mass spectrometer

1

Q-IMS-TOF Mass Spectrometry Characterization of EPDR1 Dimers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mass spectrometry measurements were performed on a Synapt G2S quadrupole-ion mobility separation-time-of-flight (Q-IMS-TOF) mass spectrometer (Waters, Manchester, UK) equipped with a nanoflow ESI (nanoESI) source. Charge states from +12 to+15 were observed for dimer in positive mode. To dissociate EPDR1 dimers, the collisional energy in the trap was increased from 5 V to 50 V.
+ Open protocol
+ Expand
2

ESI-MS Analysis of Biomolecules

Check if the same lab product or an alternative is used in the 5 most similar protocols
ESI-MS measurements were carried out in either positive or negative ion mode using a Synapt G2S quadrupole-ion mobility separation-time of flight (Q-IMS-TOF) mass spectrometer (Waters, Manchester, UK) equipped with a nanoflow ESI (nanoESI) source. Each sample solution was prepared in 500 mM aqueous ammonium acetate buffer (pH 6.8, 25°C) and loaded into a nanoESI tip, which was produced from a borosilicate capillary (1.0 mm o.d., 0.68 mm i.d.) pulled to ~5 μm using a P-1000 micropipette puller (Sutter Instruments, Novato, CA). To perform ESI, a platinum wire was inserted into the nanoESI tip and a voltage of +1.1 kV (positive ion mode) or −0.9 kV (negative ion mode) was applied. A source temperature of 60 °C was used. The Cone, Trap and Transfer voltages were 100 V, 5 V and 2 V, respectively, and the Trap gas flow rate was 6.0 mL· min−1; all other parameters were set at their default values. Data acquisition and processing were performed using Waters MassLynx software (version 4.1).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!