Nicolet is50 ft ir infrared spectrometer

Manufactured by Thermo Fisher Scientific

The Nicolet iS50 FT-IR infrared spectrometer is a laboratory instrument used for molecular analysis and identification. It employs Fourier transform infrared (FT-IR) spectroscopy to measure the absorption or transmission of infrared light by a sample, providing information about its molecular structure and composition.

Automatically generated - may contain errors

3 protocols using nicolet is50 ft ir infrared spectrometer

1

Characterization of Nanoparticle-Infused Textiles

Check if the same lab product or an alternative is used in the 5 most similar protocols
The main functional groups present in the nanoparticles, the textiles with nanoparticles and the control textiles, were analyzed by FTIR spectroscopic analysis. The samples were analyzed using a Nicolet iS50 FT-IR infrared spectrometer (Thermo Fisher Scientific), in the range of 500–4000 cm−1, with 200 scans per sample.
+ Open protocol
+ Expand
2

FTIR Analysis of PLCL and Heparin Fibers

Check if the same lab product or an alternative is used in the 5 most similar protocols
IR spectra (PLCL fibers, PLCL/heparin fibers, and heparin) were acquired using a Thermo Nicolet iS50 FTIR infrared spectrometer. Each spectrum was obtained by averaging 64 scans, and the wavenumber range spanned from 400 to 4,000 cm−1.
+ Open protocol
+ Expand
3

Comprehensive Analytical Techniques for Chemical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H NMR spectra were measured by Bruker 600 MHz nuclear magnetic resonance spectrometer. Mass spectra were obtained by Thermo Q Exactive field orbital well cyclotron resonance mass spectrometer. IR spectra (solid infrared, liquid infrared and time-resolved infrared) were carried out by Thermo Nicolet iS50 FT-IR infrared spectrometer. UV-vis spectra were measured by a Thermo Evolution-220 spectrometer. Elemental analysis was measured by a vario EL CUBE. XRD was conducted by a Bruker Smart Apex II diffractometer. EPR was measured by a Bruker EMXPLUS10/12 spectrometer. Fluorescence spectra were measured by a FluoroMax-4 spectrofluorometer. The molecular weight of protein was analyzed by Bruker Ultraflex MALDI-TOF-MS spectrometer. Agarose gel electrophoresis was performed by DYY-6C electrophoresis apparatus of Beijing Liuyi Biological Technology Co., Ltd (Beijing, China). A cytotoxicity test was measured by SpectraMax iD5 microplate reader. Confocal microscopy images were analyzed by a LSM-880 confocal laser scanning microscope.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?