The largest database of trusted experimental protocols

Gyroscanachieva 1.5 t

Manufactured by Philips
Sourced in Netherlands

The GyroscanAchieva 1.5 T is a magnetic resonance imaging (MRI) system manufactured by Philips. It operates at a field strength of 1.5 Tesla, which is a common field strength used in medical imaging. The GyroscanAchieva 1.5 T is designed to acquire high-quality MRI images for diagnostic purposes.

Automatically generated - may contain errors

2 protocols using gyroscanachieva 1.5 t

1

Magnetic Resonance Imaging Protocols for Pediatric Patients

Check if the same lab product or an alternative is used in the 5 most similar protocols
Most MR scans were performed using a 1.5-T MRI (GyroscanAchieva 1.5 T; Philips Healthcare, Best, the Netherlands) equipped with an 8-channel head coil. The scanning parameters were set as follows: T1WI (repetition time/echo time [TR/TE], 593/15 milliseconds), T2WI (TR/TE, 3720/100 milliseconds), fluid-attenuated inversion recovery (FLAIR) images (TR/TE, 11000/140 milliseconds; range of inversion times, 2400 milliseconds), and enhanced T1WI (TR/TE, 488/15 milliseconds). The remaining MR examinations were performed using a 1.5-T MRI (Signa Excite HD; GE Healthcare, Milwaukee, Wis) equipped with an 8-channel head coil. The scanning parameters were set as follows: T1WI (TR/TE, 400/11 milliseconds), T2WI (TR/TE, 4300/100 milliseconds), FLAIR images (TR/TE, 8400/120 milliseconds; range of inversion times, 2100 milliseconds), and enhanced T1WI (TR/TE, 500/20 milliseconds). All images for all sequences were 5-mm thick with an interslice gap of 1.0 mm. The matrix size was 256 × 256, and the field of view was 18 cm. The contrast agent for enhanced scan was gadopentetate dimeglumine (Bayer, Germany), injected at a dose of 0.1 mmol/kg. Uncooperative children were given chloral hydrate enema (0.5 mL/kg) sedative before the examination.
+ Open protocol
+ Expand
2

MRI Imaging Protocol for Brain Assessment

Check if the same lab product or an alternative is used in the 5 most similar protocols
1.5T MRI (GyroscanAchieva 1.5 T, Philips Healthcare, Best, Netherlands) equipped with an 8-channel head coil was used to performed the scan. The acquisition parameters were as follows: pre-contrast T1-weighted (T1-w) images (TR/TE = 593/15 ms, FOV = 18 × 18 cm, matrix = 256 × 256, slice thickness = 5 mm, spacing = 1.0 mm); T2-weighted (T2-w) images (TR/TE = 3720/100 ms, FOV = 18 × 18 cm, matrix = 256 × 256, slice thickness = 5 mm, spacing = 1.0 mm); T2/fluid-attenuated inversion-recovery (T2/FLAIR) images (TR/TE: 11000/140 ms, range of inversion time = 2400 ms, FOV = 18 × 18 cm, matrix = 256 × 256, slice thickness = 5 mm, spacing = 1.0 mm); and contrast-enhanced T1-w images (TR/TE: 488/15 ms, FOV = 18 × 18 cm, matrix = 256 × 256, slice thickness = 5 mm, spacing = 1.0 mm). Contrast MRI was performed using GD-DTPA (Bayer, Germany) at a dose of 0.1 mmol/kg.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!