Vario macro cube cn

Manufactured by Elementar
Sourced in Germany

The Vario Macro Cube CN is a laboratory instrument designed for the determination of carbon and nitrogen content in a wide range of sample types. It utilizes combustion analysis to measure these elements accurately and precisely.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using vario macro cube cn

1

Soil Characteristics Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The selected measured soil characteristics included: pH in 1 mol KCl, clay (φ < 0.002 mm), silt (φ = 0.002–0.05 mm), sand (φ = 0.05–2.0 mm), total nitrogen (TN), total carbon (TC) and total organic carbon (TOC) contents. The pH was measured potentiometrically in a 1:2.5 (m V−1) soil suspension in 1 mol L−1 KCl solution (PNISO10390, 1997). The clay content was analyzed via the aerometric method (PN-R-04032, 1998), while TN and TC were determined in a Vario Macro Cube CN elemental analyzer (Elementar Analysensysteme GmbH, Langenselbold, Germany) after dry combustion. TOC content was determined after sulfochromic oxidation followed by titration of the excess K2Cr2O7 with FeSO4(NH4)2SO4·6H2O (PN-ISO 14235, 2003).
+ Open protocol
+ Expand
2

Soil Physicochemical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
The selected soil physicochemical properties included analysis of pHKCl, clay content (φ < 0.002 mm), total carbon content (TC), total organic carbon content (TOC) as well as total nitrogen content (TN) were measured. The pH was determined according to the PN-ISO 10,390 by potentiometric method and soil suspension in 1 mol l−1 KCl solution (1:2.5 m V−1). Clay content was analyzed according to the PN-R-04032 via the aerometric method, while TN and TC were determined by dry combustion in a Vario Macro cube CN elementar analyzer (Elementar Analysensysteme GmbH, Donaustraße 7, D-63452 Hanau-Germany). TOC content was determined according to the PN-ISO 14,235 by sulfochromic oxidation with titration of excess K2Cr2O7 with FeSO4(NH4)2SO4·6H2O.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!