The largest database of trusted experimental protocols

5 protocols using 15n choline chloride

1

Isotopic Standards for Mass Spectrometry

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC grade acetonitrile and methanol, LC-MS water and 98% formic acid were obtained from Sigma-Aldrich (St. Louis, MO). A mixture of 14 stable isotopic chemicals were used as internal standards [18 (link)], including [13C6]-D-glucose, [15N]-indole, [2-15N]-L-lysine dihydrochloride, [13C5]-L-glutamic acid, [13C7]-benzoic acid, [3,4-13C2]-cholesterol, [15N]-L-tyrosine, [trimethyl-13C3]-caffeine, [15N2]-uracil, [3,3-13C2]-cystine, [1,2-13C2]-palmitic acid, [15N,13C5]-L-methionine, [15N]-choline chloride and 2’-deoxyguanosine-15N2,13C10-5’-monophosphate from Cambridge Isotope Laboratories, Inc (Andover, PA).
+ Open protocol
+ Expand
2

Isotope-Labeled Internal Standards for Metabolomics

Check if the same lab product or an alternative is used in the 5 most similar protocols
VOSO4·×H2O and KBrO3 were
purchased from Sigma-Aldrich (St. Louis, MO). Nitric acid was purchased from
MilliporeSigma (Burlington, MA). V2O5 nanoparticles were
purchased from US Research Nanomaterials, Inc. (Houston, TX). An internal
standard mixture for mass spectral analysis consisted of
[13C6]-D-glucose, [15N]-indole,
[2-15N]-L-lysine dihydrochloride,
[13C5]-L-glutamic acid,
[13C7]-benzoic acid,
[3,4-13C2]-cholesterol, [15N]-L-tyrosine,
[trimethyl-13C3]-caffeine,
[15N2]-uracil, [3,3-13C2]-cystine,
[1,2-13C2]-palmitic acid, [15N ,
13C5]-L-methionine, [15N]-choline chloride,
and
2’-deoxyguanosine-15N2,13C10-5’-monophosphate,
all from Cambridge Isotope Laboratories, Inc (Andover, Pennsylvania). Ultra-pure
water (Milli-Q; Sigma-Aldrich, St. Louis, MO) was used as indicated. All
reagents were analytical grade or better unless otherwise stated.
+ Open protocol
+ Expand
3

Comprehensive Metabolite Quantification Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC grade acetonitrile and methanol, LC-MS water and 98% formic acid were obtained from Sigma-Aldrich (St. Louis, MO). A mixture of 14 stable isotopic chemicals were used as an internal standard (Go et al. 2015 (link)) included [13C6]-D-glucose, [15N]-indole, [2-15N]-L-lysine dihydrochloride, [13C5]-L-glutamic acid, [13C7]-benzoic acid, [3,4-13C2]-cholesterol, [15N]-L-tyrosine, [trimethyl-13C3]-caffeine, [15N2]-uracil, [3,3-13C2]-cystine, [1,2-13C2]-palmitic acid, [15N,13C5]-L-methionine, [15N]-choline chloride and 2′-deoxyguanosine-15N132, C10-5′-monophosphate from Cambridge Isotope Laboratories, Inc (Andover, PA).
+ Open protocol
+ Expand
4

Targeted Metabolomics Stable Isotope Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC grade acetonitrile and methanol, LC-MS water and 98% formic acid were obtained from Sigma-Aldrich (St. Louis, MO). A mixture of 14 stable isotopic chemicals used as an internal standard [57 (link)] included [13C6]-D-glucose, [15N]-indole, [2-15N]-L-lysine dihydrochloride, [13C5]-L-glutamic acid, [13C7]-benzoic acid, [3,4-13C2]-cholesterol, [15N]-L-tyrosine, [trimethyl-13C3]-caffeine, [15N2]-uracil, [3,3-13C2]-cystine, [1,2-13C2]-palmitic acid, [15N,13C5]-L-methionine, [15N]-choline chloride and 2’-deoxyguanosine-15N2,13C10-5’-monophosphate from Cambridge Isotope Laboratories, Inc (Andover, PA).
+ Open protocol
+ Expand
5

Stable Isotopic Internal Standards for LC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Unless otherwise stated, materials were purchased from Sigma‐Aldrich. A mixture of 11 stable isotopic chemicals used as an internal standard for LC–MS analysis included [13C6]‐d‐glucose, [15N]‐indole, [15N,13C5]‐l‐methionine, [2‐15N]‐l‐lysine dihydrochloride, [15N]‐choline chloride, [13C5]‐l‐glutamic acid, [13C7]‐benzoic acid, [15N]‐l‐tyrosine, [15N2]‐uracil, [3,3‐13C2]‐cystine and [trimethyl‐13C3]‐caffeine purchased from Cambridge Isotope Laboratories, Inc. PyC2‐Gly [(γEC)2G] standard was purchased from CPC Scientific. All metal standards were purchased from either RICCA Chemical Company or Inorganic Ventures.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!