The largest database of trusted experimental protocols

Ab223864

Manufactured by Abcam

Ab223864 is a laboratory equipment product. It is a device used for the measurement and analysis of various biological samples.

Automatically generated - may contain errors

3 protocols using ab223864

1

Multiplex Biomarker Quantification in Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
ELISA kits with colorimetric output were used to determine the plasma concentrations of PAI-1 (ab184863, Abcam), fibrinogen (ab241383, Abcam), plasminogen (ab108893, Abcam), tissue plasminogen activator (t-PA) (ab190812, Abcam), platelet factor 4 (PF4) (ab189573, Abcam), interleukin (IL) 1 receptor-like 1 (ST2) (ab254505, Abcam), von Willebrand factor (vWF) (ab223864, Abcam), and tryptase (EKU10581, Biomatik) according to the manufacturer’s instructions. The plates were read at 450 nm using an automated microplate reader (Biotek Epoch). For each subject, we report the mean value from at least two replicate determinations with a coefficient of variation (CV) lower than 20%. The mean intra-assay CV was lower than 10% for all biomarkers and the inter-assay CVs were 11% for PAI-1, 10% for fibrinogen, 7% for plasminogen, 8% for t-PA, 9% for PF4, 14% for ST2, 10% for vWF, and 12% for tryptase. The plasma concentrations of each biomarker were determined using a standard curve, constructed and fit using a 4P logistic regression equation, and the assay values were corrected by the appropriate dilution factor in each case.
+ Open protocol
+ Expand
2

Comprehensive VWF Evaluation Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
We used multiple assays to comprehensively evaluate VWF, including: 1) VWF antigen (VWF:Ag) and VWF propeptide (VWF:pp) measured by enzyme-linked immunosorbent assay (Cat #: ab223864 [Abcam] and CS-MW1939 [Cell Sciences]); 2) thiols exposed on the surface of VWF multimers (Supplemental Methods); 3) ristocetin-induced platelet agglutination (RIPA) (Helena Laboratories); 4) VWF binding to collagen (VWF:CB) (Supplemental Methods); 5) platelet adhesion under flow conditions (Supplemental Methods); 6) VWF multimers using nonreducing sodium dodecyl sulfate–agarose gel electrophoresis (Supplemental Methods);27 (link) 7) shear-induced platelet aggregation (SIPA) (Supplemental Methods); 8) the exposure of the A1 domain on VWF using immunoprecipitation (Supplemental Methods); 9) endothelial permeability (Supplemental Methods); and 10) ADAMTS-13 antigen (ADAMTS-13:Ag) using enzyme-linked immunosorbent assay (Cat #: ab234559; Abcam) and cleaving an exogenous VWF peptide measured using a FRET (fluorescence resonance energy transfer) assay (Diapharma).
+ Open protocol
+ Expand
3

Endothelial Dysfunction Biomarker Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma samples were processed and handled according to the manufacturer’s instructions for each of the assays: syndecan-1 (abcam, ab46506), vWF (abcam, ab223864). All samples and standards were run in duplicate for each marker of endothelial dysfunction.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!