The largest database of trusted experimental protocols

Tim trio 3t mr

Manufactured by Siemens

The Tim Trio 3T MR is a magnetic resonance imaging (MRI) system that operates at a static magnetic field strength of 3 Tesla. It is designed to capture high-quality, detailed images of the body's internal structures.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using tim trio 3t mr

1

Functional MRI Acquisition Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood oxygenation level dependent (BOLD) contrast functional images were acquired with echo-planar T2*-weighted imaging (EPI) using a Siemens Tim Trio 3T MR system with a 12 channel head coil. Each image volume consisted of 26 sequential 3 mm thick slices (interslice gap, 0.75 mm; in-plane resolution, 2.4 × 2.4 mm; field of view, 234 by 234 mm; matrix size, 98 by 98; flip angle, 74 degrees; echo time, 33 ms; repetition time, 2 s). Slice acquisition was transverse oblique, angled to avoid the eyes, and provided near whole brain coverage. These acquisition parameters were chosen to minimize voxel size while covering all brain regions of interest. In some subjects, cerebellum and part of motor cortex was not covered by our slice prescription. To aid co-registration, an additional eight echo-planar volumes were acquired using the same parameters as the task data but with an increased number of slices and adjusted TR. Data were acquired in nine scanning runs lasting approximately 5 min each. The first five volumes of each run were discarded to allow for T1 equilibration effects. A T1-weighted structural scan was also acquired at 1 mm isotropic resolution. This was acquired prior to the functional data.
+ Open protocol
+ Expand
2

BOLD Contrast Imaging Protocol for fMRI

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood oxygenation level dependent (BOLD) contrast functional images were acquired with echo-planar T2*-weighted imaging (EPI) using a Siemens Tim Trio 3T MR system with a 12 channel head coil. Each image volume consisted of 48 interleaved 2 mm thick slices (interslice gap, 0.5 mm; inplane resolution, 3 × 3 mm; matrix size, 64 × 64; repetition time, 3 s; echo time, 30 ms; flip angle, 90°; bandwidth, 2232 Hz). Slice acquisition was transverse oblique, angled to avoid the eyes as far as possible while maintaining coverage of ventral temporal cortex. Data were acquired in five scanning runs of approximately 8 min. The first five volumes of each run were discarded to allow for T1 equilibration effects. T1-weighted structural images were acquired at a resolution of 1 × 1 × 1 mm.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!