The largest database of trusted experimental protocols

2 protocols using anti bcl xl

1

Protein Expression Analysis of Apoptotic Regulators

Check if the same lab product or an alternative is used in the 5 most similar protocols
Protein extraction was carried out with approximately 2 × 106 cells treated for 6, 16, 24, and 48 h with OXC or Paclitaxel at the corresponding IC50 using a lysis buffer (20 mM Tris HCl pH 8.0, 137 mM NaCl, 10% glycerol, 1% NP-40, and 10 mM EDTA). The total protein concentration was determined by the Bicinchoninic Acid (BCA) Protein Assay Kit (Pierce), and 25 µg of protein from each sample were subjected to 11% SDS-PAGE polyacrylamide gel electrophoresis using a mini-gel system (mini-Protean II; Bio-Rad Laboratories). Proteins were blotted using polyvinylidene fluoride membranes (PVDF). The transferred membranes were blocked for 1 h with 5% BSA/TTBS (w/v), followed by overnight incubation at 4 °C with the primary antibodies: anti-Bim, anti-Bax, anti-Bcl-2, anti-Bcl-xL, anti-Caspase-7 (GeneTex, Irvine, CA, USA), or anti-Caspase-3 (Thermo Fisher Scientific, Waltham, MA, USA), and anti-α-tubulin (Merck Group, DE, Darmstadt, Germany) was used as a loading control. On the next day, the membranes were incubated with the corresponding secondary antibody, either anti-Mouse IgG or anti-Rabbit IgG (Merck Group, DE, Darmstadt, Germany), for 1 h at room temperature. Bands were visualized on PVDF membranes using the 3,3′-diaminobenzidine tetrahydrochloride (DAB) Substrate Kit detection method (Pierce). ImageJ software was used to semi-quantify and compare band density [5 (link)].
+ Open protocol
+ Expand
2

Benzyl Isothiocyanate Induces Apoptosis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Benzyl isothiocyanate (BITC), cisplatin, dimethyl sulfoxide (DMSO), 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT), and other chemicals of analytical grade were acquired from Sigma-Aldrich (St. Louis, MO, USA) unless otherwise specified. Dulbecco’s modified Eagles medium (DMEM), fetal bovine serum (FBS), L-glutamine, and penicillin/streptomycin were purchased from HyClone (Logan, UT, USA). ZVAD-fmk (a pan-caspase inhibitor) was purchased from Merck Millipore (Billerica, MA, USA). Caspase-3 and Caspase-9 Colorimetric Assay Kits were obtained from R&D Systems (Minneapolis, MN, USA). 2’,7’-Dichlorodihydrofluorescein diacetate (H2DCFDA) (an ROS indicator) and 3,3’-dihexyloxacarbocyanine iodide [DiOC6(3)] [a mitochondrial membrane potential (Δψm) detector] were purchased from Molecular Probes/Thermo Fisher Scientific (Waltham, MA, USA). The anti-Bax, anti-Bad, anti- Bcl-2, anti-Bcl-xL, anti-cytochrome c, anti-caspase-9, anti-Caspase-3, and anti-β-actin, as well as anti-rabbit IgG or anti-mouse horseradish peroxidase (HRP)-linked antibodies were all bought from GeneTex (Hsinchu, Taiwan).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!