The largest database of trusted experimental protocols

Win epr simfonia software version 1

Manufactured by Bruker
Sourced in United States

WIN-EPR SIMFONIA software, version 1.2, is a product from Bruker. It is an application software used for the simulation of electron paramagnetic resonance (EPR) spectra.

Automatically generated - may contain errors

2 protocols using win epr simfonia software version 1

1

Spectroscopic Characterization of Cu2+ Solutions

Check if the same lab product or an alternative is used in the 5 most similar protocols
The absorption spectra of Cu2+ containing solutions were recorded on a Varian Cary50 Probe spectrophotometer, in the range 350–900 nm, using a quartz cuvette with an optical path of 1 cm. To describe the species present in solution, the observed wavelength of maximum absorption at a given pH was compared with the expected λmax value obtained from literature23 (link),48 (link)–50 (link). Circular dichroism (CD) spectra were recorded on a Jasco J-1500 spectropolarimeter in the 180–800 nm range, using a quartz cuvette with an optical path of 1 cm in the visible and near-UV range, and 0.01 cm in the 180–250 nm range. Electron paramagnetic resonance (EPR) spectra were recorded in liquid nitrogen on a Bruker ELEXSYS E500 CW-EPR spectrometer at X-band frequency (9.5 GHz) and equipped with an ER 036TM NMR teslameter and an E41 FC frequency counter. Ethylene glycol (30%) was used as a cryoprotectant. The EPR parameters were analyzed by computer simulation of the experimental spectra using WIN-EPR SIMFONIA software, version 1.2 (Bruker, Billerica, MA, USA).
+ Open protocol
+ Expand
2

Spectroscopic Characterization of Laz Protein

Check if the same lab product or an alternative is used in the 5 most similar protocols
The visible-spectra were recorded on a Shimadzu UV-1800 spectrophotometer using 1 cm quartz cells. Laz samples were oxidized with a solution of potassium ferricyanide and reduced with a solution of sodium ascorbate.
The Laz sample for EPR was 0.3 mM in 20 mM phosphate buffer, pH 7.0. The EPR spectra of Laz were recorded on a X-band Bruker EMX Fig. 1. Analysis of the primary sequence of Ng Laz. In green underlined is the signal peptide recognized by the signal peptidase II pathway; in blue are identified the residues of the mature protein recognized by the epitope for the H.8 MAb; and in black the azurin-like domain.
spectrometer equipped with a rectangular cavity (model ER 4102T) and an Oxford Instruments continuous liquid helium flow cryostat. Experimental conditions are described in the legend of the spectrum. The simulation of the spectrum was performed using WINEPR SimFonia software version 1.2, from Bruker.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!