The largest database of trusted experimental protocols

Bio plex pro human inflammation panel

Manufactured by Bio-Rad
Sourced in United States

The Bio-Plex Pro Human Inflammation Panel is a multiplex assay designed to measure the levels of multiple inflammation-related proteins simultaneously in a single sample. The panel allows for the quantification of up to 40 different analytes, providing a comprehensive assessment of the inflammatory state.

Automatically generated - may contain errors

2 protocols using bio plex pro human inflammation panel

1

Cytokine Profiling in Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
We collected peripheral blood from all subjects in acid-citrate dextrose Vacutainers (BD Biosciences, San Jose, CA, USA). Plasma was obtained from blood by centrifugation at 2100 rpm for 10 min. Then, the plasma was separated, aliquoted, and stored at − 80 °C for further cytokine analysis. A panel of four cytokines (MMP-1, MMP-3, osteopontin, and pentraxin-3) was measured in the plasma for Bio-plex Pro human inflammation panel (Bio-Rad, 17008653, Hercules, CA, USA) detection. We ran one sample per subject at one time, in line with the operating protocol. First, we incubated a 25-μl plasma sample with antibody-coupled fluorescent beads. Second, we washed and incubated the sample with biotinylated detection antibodies detected by streptavidin–phycoerythrin. Third, a flow-based Luminex 100 suspension array system (Bio-plex 200; Bio-Rad Laboratories, Inc.) was used to analyze the beads. To determine the sample concentration, standard curves were generated by Bio-plex Manager software, and in the kit, the reference cytokines were provided by the manufacturer. Other inflammation cytokines (tumour necrosis superfamily member 13B [TNFSF/BAFF], IL-29/interferon [IFN]-λ2, IL-32, TWEAK/TNFSF12, and sCD30/TNFRSF8, IFN-γ, IL-10, IL-12p70, IL-17A, IL-1β, IL-2, IL-4, IL-6, and TNF-α) were assessed with the same method in our previous research [11 (link)].
+ Open protocol
+ Expand
2

Comprehensive Evaluation of Inflammation and Apolipoproteins

Check if the same lab product or an alternative is used in the 5 most similar protocols
We also assumed that for the evaluation of inflammatory response and apolipoprotein levels in serum the Bio-Plex Pro Human Apolipoprotein Assay Panel and Bio-Plex Pro Human Inflammation Panel (Bio-Rad, Hercules, California, USA) will be used. Concentrations of apolipoproteins, such as Apo A1, Apo A2, Apo B, Apo C1, Apo C3, Apo D, Apo E, Apo H, and Apo J, will be determined. The analysis of biomarkers of inflammation will include: C-reative protein (CRP), Treg cytokines (IL-2, IL-10, IL-12, IL-19, IL-20, IL-22, IL-26, IL-27, IL-35, and interferon (IFN)-λ2 and IFN-λ1), matrix metalloproteinases (MMP-1, MMP-2, MMP-3), tumour necrosis factor (TNF) superfamily proteins, and IFN family proteins (APRIL/TNFSF13, BAFF/TNFSF13B, sCD30/TNFRSF8, sCD163, chitinase-3-like 1, gp130/sIL-6Rβ, IFN-α2, IFN-β, IFN-γ, sIL-6Rα, IL-8, IL-11, IL-32, IL-34, LIGHT/TNFSF14, osteocalcin, osteopontin, pentraxin-3, sTNF-R1, sTNF-R2, TSLP, and TWEAK/TNFSF12).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!