The largest database of trusted experimental protocols

3 protocols using 1.2 dipalmitoyl sn glycero 3 phospho 1 rac glycerol sodium salt dppg

1

Lipid-based Nanoparticle Formulation

Check if the same lab product or an alternative is used in the 5 most similar protocols
1.2-dipalmytoil-sn-glycero-3-phosphocholine (DPPC), cholesterol (ovine wool), L-α-phosphatidylcholine (Soy PC), 1.2-dipalmitoyl-sn-glycero-3-phospho-(1′-rac-glycerol) (sodium salt) (DPPG) and Avanti Mini-Extruder were purchased from Avanti Polar Lipids, Alabama. Histamine dihydrochloride, poly (ethylene glycol) (PEG, MW 8000), dextran (from Leuconostoc spp. MW 450000-600000) were obtained from Sigma-Aldrich, Sweden. Whatman nucleopore track-etched polycarbonate membranes, pore size 5 μm and Thermo Scientific Slide-A-Lyzer Dialysis Cassettes (10K MWCO) were purchased from Fisher Scientific, Sweden.
+ Open protocol
+ Expand
2

Liposome Formulation and Preparation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Phospholipids 1,2- dipalmitoyl-sn-glycero-3-phosphocholine (DPPC), 1,2-dioleoyl-sn-glycero- 3-phosphocholine (DOPC) and 1,2-dipalmitoyl-sn-glycero-3-phospho-(1′-rac- glycerol) (sodium salt) (DPPG) were purchased from Avanti Polar Lipids, Inc. (Alabaster, Alabama). A 10 mg/ml cholesterol solution and mannitol was purchased from Sigma Aldrich (St. Louis, Missouri). DPPC, DOPC, DPPG and cholesterol were mixed in the molar ratio 46:23:23:8 in a round bottom flask and placed in a rotary evaporator at 52 °C for 45–60 minutes (Eyela rotary evaporator, Tokyo Rikakikai Corporation Ltd., Product # N-1001, Bohemia, New York). The flask was placed in a vacuum desiccator for 3–4 hours to ensure complete removal of solvent.
+ Open protocol
+ Expand
3

Radiolabeled Lipid Nanoparticle Formulation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lipids of 1,2‐distearoyl‐sn‐glycero‐3‐phosphocholine (DSPC) and 1,2‐dipalmitoyl‐sn‐glycero‐3‐phospho‐(1′‐rac‐glycerol) (sodium salt) (DPPG) were purchased from Avanti Polar Lipids (Alabaster, AL, USA). Polyethylene glycol (MW: ∼4000, PEG), mannitol, palmitic acid, and perfluoroheptane were purchased from Sigma‐Aldrich (St. Louis, MO, USA). Sulfur hexafluoride and oxygen were purchased from Jietong Gas Technology (Guangzhou, China). 125I seeds (Type 6711, diameter: 0.8 mm, length: 4.5 mm, matched peripheral dose: 100–140 Gy) were purchased from Yunke Pharmaceutical (Chengdu, China). All aqueous solutions were prepared in Milli‐Q deionized water (18 MΩ cm−1, Millipore, MilliQ system).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!