The largest database of trusted experimental protocols

Polyethersulfone filters

Manufactured by GE Healthcare

Polyethersulfone filters are a type of lab equipment used for filtration in various applications. These filters are designed to effectively remove particulates, macromolecules, and other contaminants from liquid samples. They are known for their durability, chemical resistance, and ability to maintain high flow rates during the filtration process.

Automatically generated - may contain errors

2 protocols using polyethersulfone filters

1

Lentiviral Gene Transduction in HEK293T Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
For lentiviral gene transduction, HEK293T cells transfected with the respective lentiviral vectors and packaging plasmids psPAX2 and pMD2.G using Polyfect (QIAGEN) or PEI. 24h later, medium was exchanged to RPMI, supplemented with 10% (v/v) FBS and antibiotics (100 U/ml penicillin, 100 mg/ml streptomycin). 48h after transfection, cell supernatants were harvested, filtered through 0.45 μm polyethersulfone filters (GE Healthcare) and supplemented with 8 μg/ml protamine sulfate (Sigma). Cells were infected by spinfection (2000 rpm, 45 minutes, room temperature). 24h after infection, medium was changed, 48h after infection, cells were selected with the respective antibiotics.
+ Open protocol
+ Expand
2

Lentiviral Gene Transduction in HEK293T Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
For lentiviral gene transduction, HEK293T cells transfected with the respective lentiviral vectors and packaging plasmids psPAX2 and pMD2.G using Polyfect (QIAGEN) or PEI. 24h later, medium was exchanged to RPMI, supplemented with 10% (v/v) FBS and antibiotics (100 U/ml penicillin, 100 mg/ml streptomycin). 48h after transfection, cell supernatants were harvested, filtered through 0.45 μm polyethersulfone filters (GE Healthcare) and supplemented with 8 μg/ml protamine sulfate (Sigma). Cells were infected by spinfection (2000 rpm, 45 minutes, room temperature). 24h after infection, medium was changed, 48h after infection, cells were selected with the respective antibiotics.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!