Fluorolog 2

Manufactured by SPEX

The Fluorolog 2 is a fluorescence spectrometer designed for accurate and reliable measurements of fluorescent samples. It is capable of performing steady-state fluorescence measurements, providing researchers with a versatile tool for their laboratory applications.

Automatically generated - may contain errors

3 protocols using fluorolog 2

1

Characterization of Organic Semiconductors

Check if the same lab product or an alternative is used in the 5 most similar protocols
The evaporation of the samples on quartz substrates was carried out using an Edwards Auto 306 evaporator equipped with a high vacuum chamber (10−6 mbar) and a frequency thickness monitor (FTM) to check the evaporation rate. The deposition rate was 0.5 nm∙s−1 with a final thickness of 80 nm. The solid state absorption spectra were recorded on a Perkin-Elmer Lamba 900 UV–vis–NIR spectrophotometer, the photoluminescence spectra of Alq3 and Al(Op)3 were acquired on a Spex Fluorolog 2. The photoluminescence quantum yield in solid state was estimated by the absolute method using an integrating sphere [44 (link)]. The lifetimes were obtained on a time-correlated single photon counter (TCSPC) equipped with a NanoLED source and a Horiba Jobin-Yvon Fluorohub for the data elaboration.
+ Open protocol
+ Expand
2

Optical Characterization of Tissue Phantoms

Check if the same lab product or an alternative is used in the 5 most similar protocols
For the experimental tests presented in this paper, a set of liquid homogeneous phantoms representative of GI tissues was considered, with different concentrations of Hb, polystyrene beads (1 μm diameter), and the fluorophores NADH and Carbostyril 124 (7-amino-4-methyl-2(1H)-quinolinone, representative of collagen). The structures of both fluorophores are shown below (Figure 2). For each phantom created, its diffuse reflectance signal was obtained, between 350 nm and 750 nm, with a commercial UV-Vis-NIR spectrophotometer (Shimadzu UV 3101PC) equipped with an integrating sphere. The fluorescence signal was obtained, between 380 nm and 600 nm (with excitation at 350 nm), using a commercial fluorometer (SPEX® FluoroLog® 2), equipped with a temperature controlled cuvette holder. Temperature was kept constant at the chosen value ±0.2 °C. All the fluorescence spectra were corrected for the instrumental response of the equipment (using the correction curve provided by the manufacturer). The influence of intensity fluctuations of the lamp was eliminated by the acquisition system (dividing the sample signal by a reference signal acquired by a photodiode). Therefore, fluorescence signal has no variability for each of the samples at a given temperature.
+ Open protocol
+ Expand
3

Spectroscopic Characterization of DNA

Check if the same lab product or an alternative is used in the 5 most similar protocols
UV/vis absorption spectra over the range 230-500 nm were recorded with a Varian Cary 300 spectrometer. Measurements were performed in a double cuvette (closed but not evacuated) having sections of 1 and 10 mm optical path length. An equivalent cuvette with pure solvent was used for reference. In melting experiments, after each rising temperature step of 5 1C the sample and holder were allowed to equilibrate for 10 minutes. A total concentration c T = 20.5 mM of single strands was estimated. Spectra between 20 and 80 1C were recorded and corrected for density change. Fluorescence spectra at 25 1C were obtained on a Spex Fluorolog-2, by photometric comparison with a secondary standard lamp. Wavelength axes were calibrated with a holmium glass filter or a Hg lamp.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!