Dawn heleos 18 angle detector

Manufactured by Wyatt Technology
Sourced in United States

The DAWN HELEOS 18-angle detector is a multi-angle light scattering instrument designed for the characterization of macromolecules and nanoparticles. The device measures the intensity of light scattered by a sample at 18 different angles, providing detailed information about the size, shape, and molecular weight of the analyzed particles.

Automatically generated - may contain errors

2 protocols using dawn heleos 18 angle detector

1

HPLC-SEC-MALS Analysis of Sample Composition

Check if the same lab product or an alternative is used in the 5 most similar protocols
Relevant samples were analyzed by HPLC‐SEC‐MALS in order to determine particle composition and estimate purity. All experiments were performed using the HPLC system mentioned in 2.11 with the Chromeleon 7 software (Thermo Fisher Scientific) for method programming, control and data acquisition. A TSKgel G5000PWXL column (300.0 × 7.8 mm i.d.) combined with a TSKgel PWXL guard column (40.0  × 6.0 mm i.d.) (Tosoh Bioscience, Stuttgart, Germany) was used. A volume of 50 µL of each sample was injected. The flow rate was 0.3 mL/min. Isocratic elution was performed with 50 mM HEPES, 100 mM NaCl, pH 7.2. UV signals at 280 and 260 nm were recorded by the Chromeleon software and LS signal was acquired with a DAWN HELEOS 18‐angle detector (Wyatt) with the Astra Software 5.3.4 (Wyatt). Data evaluation was performed in Astra 6.1.2.
+ Open protocol
+ Expand
2

MALS Analysis of Biomolecular Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
At‐line MALS measurements for the determination of the LS intensity were performed using an Ultimate 3000 HPLC system (Thermo Fisher) with a quaternary LPG‐3400SD pump, a WPS‐3000TSL autosampler, and a DAD 3000 UV‐detector. Mobile phase consisted of 50 mM HEPES, 100 mM NaCl, pH 7.2. A sample volume of 50 µL was injected in bypass mode using a flow rate of 0.3 mL/min. All samples were measured in duplicates. MALS signals were acquired by the DAWN HELEOS 18‐angle detector (Wyatt, Santa Barbara, CA, USA). For HPLC programming, Chromeleon 7 software (Thermo Fisher) was used. MALS data collection and analysis were performed with ASTRA software, version 6.1.2 (Wyatt).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!