The largest database of trusted experimental protocols

2 protocols using 1 3 cyclopentanediol

1

Fractional Distillation of 1,3-Cyclopentanediol

Check if the same lab product or an alternative is used in the 5 most similar protocols
1,3-Cyclopentanediol from Sigma Aldrich was obtained as an cis/trans enantiomeric mixture having >95% purity. The commercial batch was analyzed prior to use via NMR and chiral GC to determine the cis/trans ratio, and was found to be 15/85 cis/trans (see ESI for analysis). Based on the different boiling point of the cis/trans enantiomers, the commercial batch was purified by fractional distillation under vacuum. Various cis/trans ratios were obtained via batch-wise fractional distillation; Generally, 1,3-Cyclopentanediol was loaded in a 50 mL 2-neck round-bottom flask, equipped with a 10 cm vigreux column, distillation 3-way adapter, condenser path, and a vacuum adapter to collect different fractions. Temperature of the oil-bath was varied from 130 °C to 160 °C. Temperature of the boiling phase was measured in the 3-way adapter, and the depth of the vacuum was noted. All fractions were obtained either as colorless liquids or as colorless solids: 7.6% cis (110 °C, 0.85 mbar), 14% cis (125 °C, 1.4 mbar), 20.7% cis (120 °C, 1.6 mbar), 30% cis (116 °C, 1.2 mbar), 41% cis (111 °C, 1.3 mbar).
+ Open protocol
+ Expand
2

Synthesis of Furan-Based Polyesters

Check if the same lab product or an alternative is used in the 5 most similar protocols
1,3-Cyclopentanediol (15/85 cis/trans), 1,4-cyclohexanedimethanol (38/62 cis/trans), adipoyl chloride, sebacoyl chloride, terephthaloyl chloride, tin(ii) 2-ethyl-hexanoate, and anhydrous chloroform, DMF, THF, and toluene were obtained from Sigma Aldrich. Magnesium(iv) sulfate, 4-dimethylaminopyridine and pyridine were obtained from ACROS. 2,5-Furan-dicarboxylic acid was obtained from ABCR. 1,4-Cyclohexanediol (46/54 cis/trans) was obtained from Alfa Aesar. Ethylene glycol was obtained from TCI. Standard laboratory solvents were obtained from Biosolve. Deuterated solvents were obtained from Buchem BV (Netherlands). The purchased compounds were used directly without further purification, unless otherwise specified.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!