The largest database of trusted experimental protocols

13 protocols using 2 hydroxybenzaldehyde

1

Protein-Ligand Interaction Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Materials used for the experiments done in the current work were employed in the experiments without further purifications. From Merck, 2-hydroxybenzaldehyde, N-methyl propane 1,3-diamine, imidazole, methanol, CuCl2·2H2O, Ni(ClO4)2·6H2O etc. were procured. BSA and DNA was purchased from Sigma-Aldrich Chemicals (USA) and was prepared in 10 mM Phosphate Buffer (pH 7.4). For steady-state and time-resolved experiments, the concentration of BSA was kept as 5 μM, whereas 2 μM BSA was used for Circular Dichroism (CD) spectroscopic studies.
+ Open protocol
+ Expand
2

Synthesis of Organotin(IV) Complexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
2-Hydroxy benzaldehyde, 3-hydroxy benzaldehyde, 4-hydroxy benzaldehyde, 2-nitro benzaldehyde, 3-nitro benzaldehyde, 4-nitro benzaldehyde, 2-hydroxy, 3-methoxy benzaldehyde, 4-hydroxy, 3-methoxy benzaldehyde, malonic acid, ammonium acetate, acetyl chloride, dibutyltin(iv) oxide, dibutyltin(iv) dichloride, tributyltin(iv) chloride, triphenyltin(iv) chloride and tricyclohexyltin(iv) chloride were purchased from Merck Company (Germany). Melting points were determined by Fisher-Johns melting point apparatus (USA) and were found uncorrected. An Eager 300 mass analyzer (USA) was used for elemental analyses. A Bruker FTIR (USA) spectrophotometer TENSOR27 (ZnSe) was used to record the FTIR spectra of the pure solid samples covering 4000–400 cm−1. EI-MS spectra were observed in terms of % m/z on a Finnigan MAT 312 spectrometer (USA). 1H, 13C and 119Sn NMR spectra were calculated with a Bruker AM 400 NMR spectrometer (USA).
+ Open protocol
+ Expand
3

Antimalarial Compound Screening Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The reagents, including 2-hydroxybenzaldehyde, 3-hydroxybenzaldehyde, cyclohexanone, cyclopentanone, acetone, ethanol, tetrahydrofuran, and sodium hydroxide, were purchased from Merck in pro analysis specification. In addition, hydrochloric acid was purchased from Mallinckrodt, while the materials used in the antimalarial evaluation include RPMI-1640, serum-blood, RBC (Red Blood Cell), curcumin, dimethyl sulfoxide (DMSO), and three-dimensional structure of PfATP6 (PDB ID: 2OA0).
+ Open protocol
+ Expand
4

Synthesis and Characterization of Schiff Base Complexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chemicals and reagents were purchased from commercial sources. 2-Hy­droxy­benzaldehyde, 2-meth­oxy­aniline and an­hydrous MII halides, where M is Zn, Cd and Hg, were pur­chased from Sigma–Aldrich and Merck, and used as received. The Schiff base ligand 2-{[(2-meth­oxy­phen­yl)imino]­meth­yl}phenol (L) was prepared according to a previously reported method (Song et al., 2013 ▸ ). The IR spectra were recorded on a Nicolet FT–IR 100 spectrometer in the range 500–4000 cm−1 using the KBr disk technique. Elemental analyses (C, H and N) were performed using an ECS 4010 CHN-O made in Costech, Italy. Melting points were measured by an Electrothermal 9100 melting-point apparatus and corrected. The measurements were carried out using 10 mg of a powdered sample sealed in aluminium pans with a mechanical crimp.
+ Open protocol
+ Expand
5

Analytical Standards of Phenolic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analytical standards of 2,5-dihydroxybenzaldehyde (compound 2; 98% purity), m-cresol (3; 99% purity), 3-hydroxybenzyl alcohol (4; 99% purity), toluquinol (5; ≥98% purity), 3-hydroxybenzaldehyde (6; ≥99% purity), 3-hydroxybenzoic acid (7; 99% purity), 2,5-dihydroxybenzoic acid (8; 98% purity), 2,4-dihydroxybenzaldehyde (10; 98% purity), 3,4-dihydroxybenzaldehyde (11; 97% purity), 3,5-dihydroxybenzaldehyde (12; 98% purity), 2-hydroxybenzaldehyde (13; 98% purity), and 4-hydroxybenzaldehyde (14; 98% purity) were procured from Sigma-Aldrich, Seoul, Korea. Methanol, acetone, and water used for the following experiments were of high-performance liquid chromatography (HPLC) grade.
+ Open protocol
+ Expand
6

Chitosan-Based Diclofenac Delivery

Check if the same lab product or an alternative is used in the 5 most similar protocols
Low-molecular-weight chitosan (193 kDa, DD = 82%), 2-hydroxybenzaldehyde (98%), ethanol, acetic acid, phosphate buffer (PBS) (pH = 7.4), and diclofenac sodium salt (DCF) were procured from Sigma-Aldrich (St. Louis, MO, USA) and used as received.
+ Open protocol
+ Expand
7

Synthesis of Substituted Benzaldehydes

Check if the same lab product or an alternative is used in the 5 most similar protocols
3-anisaldehyde (97%), 4-anisaldehyde (99+%), 3-tolualdehyde (98%), 3-nitroBenzaldehyde (99%), and 3-bromoBenzaldehyde (96%) were acquired from Acros organics (NJ, USA). 2-hydroxyBenzaldehyde, ethyl acetoacetate (99%), 4-hydroxyBenzaldehyde, 4-nitroBenzaldehyde (98%), 4-cloroBenzaldehyde (97%), 4-bromoBenzaldehyde (99%), ethyl vanillin (98%), piperonal (99%), and piperidine (≥99.5%) were purchased from Sigma-Aldrich Co. (St. Louis, MO, USA). Benzaldehyde was obtained from Merck (Hohenbrunn, Germany) and Aldrich Co. (Milwaukee, WI, USA).
+ Open protocol
+ Expand
8

Synthesis of Fluorinated Benzaldehyde Complexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
All manipulations were performed under an inert atmosphere using Schlenk-line techniques (O2 < 3 ppm) and a glove box (O2 < 0.6 ppm) MBraun MB-20G (MBraun, Garching, Germany). Solvents were purified using an MBraun Solvent Purification System (MBraun, Garching, Germany). Deuterated solvents were degassed and stored in the glove box in the presence of molecular sieves (4 Å). Fluoroaniline compounds were purchased from Fluorochem (Fluorochem, Derbyshire, UK) and used as received. 2-hydroxybenzaldehyde and metallic precursors were purchased from Sigma-Aldrich (Merck, Darmstadt, Germany). NMR spectra were recorded with a Bruker 400 Ultrashield (Bruker, Karlsruhe, Germany) (1H 400 MHz, 13C 101 MHz) at room temperature. All chemical shifts were determined using the residual signal of solvents and were reported versus SiMe4. The assignment of the signal was carried out from 1D (1H, 19F{1H}, 13C{1H}) and 2D (1H-13C HSQC) NMR experiments. Elemental analyses were performed with a PerkinElmer 2400 CHNS/O analyzer Series II (PerkinElmer, Ohio, OH, USA) and were the average of at least two independent measurements.
+ Open protocol
+ Expand
9

Chitosan-based Heavy Metal Adsorbents

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents used were of analytical reagent grade stated. Chitosan (CS) (with DDA 64% from IR chart) was extracted from shrimp shell were purchased from local market. Sodium hydroxide (NaOH, 97%) was purchased from Scharlau. Hydrochloric acid (HCl, 37%) and Glacial Acetic acid (CH3COOH, 99.8%) were purchased from Merck. CuSO4.5H2O (99%) and ZnSO4.7H2O (99–100.5) were purchased from Sigma-Aldrich, Merck respectively. Cr2(SO4)3.15H2O (99%) and 3-dichloropropane (98%) were purchased from Riedel-De Haen AG. Na2CO3 (≥ 99.5%) and EDTA (99.4–100.6%) were purchased from BDH. absolute Ethanol and 2-hydroxybenzaldehyde were purchased from Sigma-Aldrich.
+ Open protocol
+ Expand
10

Synthesis of Photoacid for Optical Applications

Check if the same lab product or an alternative is used in the 5 most similar protocols
Photoacid was synthesized according to literature22 (link),23 (link). First, 2,3,3-trimethylindolenine (3.18 g, 20 mmol, 98%; Sigma-Aldrich) was mixed with 1,3-propanesultone (2.44 g, 20 mmol, >99%; Sigma-Aldrich) and then heated to 90 °C for 6 h under nitrogen protection. The product was collected as a purple solid by filtration and washed thoroughly with diethyl ether. The dried product (600 mg, 2.14 mmol) and 292 mg of 2-hydroxybenzaldehyde (2.4 mmol, >99.0%; Sigma-Aldrich) were then added to 12.0 mL of anhydrous ethanol, and the solution was refluxed overnight. The resulting orange solid was collected by filtration and rinsed thoroughly with ethanol (5 × 10 mL). The final product was dried in vacuum and stored in a freezer (−20 °C) under nitrogen protection. The pH of the photoacid solution was measured by a Mettler Toledo SevenExcellence pH meter.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!