The largest database of trusted experimental protocols

Powerchrom

Manufactured by Eicom

PowerChrom is a high-performance liquid chromatography (HPLC) system designed for analytical and preparative applications. The core function of PowerChrom is to separate, identify, and quantify components in a sample mixture.

Automatically generated - may contain errors

2 protocols using powerchrom

1

Microdialysis of Dopamine in Mouse NAc

Check if the same lab product or an alternative is used in the 5 most similar protocols
Microdialysis was performed as described previously22 (link)46 (link). Briefly, the animals were anesthetized with sodium pentobarbital, and surgery was performed to implant a guide cannula (AG-4; EICOM, Kyoto, Japan) into the nucleus accumbens. On the following day, a dialysis probe (AI-4-1, 1-mm membrane length; EICOM) was inserted through the guide cannula and was perfused with artificial cerebrospinal fluid (148 mM NaCl, 2.7 mM KCl, 1.2 mM CaCl2, and 0.85 mM MgCl2) at a flow rate of 1 μl min–1. After an equilibration period of one hour, samples were collected every 20 minutes. After collection of at least five baseline fractions, mice were administered MAP (1 mg kg–1, i.p.), and 6 more fractions of samples were collected. The concentration of dopamine in the samples was measured by HPLC on a 4.6 by 30 mm PP-ODS column (EICOM) that was maintained at 25 °C and equipped with an electrochemical detection system (HTEC-500, EICOM) and PowerChrom (EICOM).
+ Open protocol
+ Expand
2

HPLC-ECD Analysis of 5-HT in Dialysate

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 5-HT level in the dialysate sample was analyzed by an HPLC system with electrochemical detection (HPLC-ECD) (HTEC-500, Eicom Co.). A 20-μl sample was injected into an HPLC-ECD system that included an EICOMPAK CAX column (2.0 mm i.d. ×200 mm, Eicom Co.) and was set at a potential of +450 mV against a Ag/AgCl reference electrode with a graphite carbon working electrode (WE-3G, Eicom Co.). The mobile phase consisted of 0.08 M sodium sulfate-0.1 M ammonium acetate buffer (pH 6.0) containing 30% (v/v) methanol and 50 mg/l Na2EDTA. Separations were conducted at 35°C with a flow rate of 0.25 ml/min. The standard 5-HT solution was injected every working day, and the amount of 5-HT in the samples was calculated on the basis of standard values using PowerChrom (version 2.2.4, Eicom Co.).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!