The largest database of trusted experimental protocols

8 protocols using lycopsamine

1

Comprehensive Analytical Standards for Pyrrolizidine Alkaloids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analytical standards of all pyrrolizidine alkaloids and their N-oxide were purchased from Phytolab (Vestenbergsgreuth, Germany): Echimidine (Em), Echimidine-N-oxide (EmNO), Echinatine (En), Echinatine-N-oxide (EnNO), Erucifoline-N-oxide (ErNO), Europine (Eu), Europine-N-oxide (EuNO), Heliosupine (Hs), Heliosupine-N-oxide (HsNO), Heliotrine (Ht), Heliotrine-N-oxide (HtNO), Indicine (Id), Indicine-N-oxide (IdNO), Integerrimine (Ir), Integerrimine-N-oxide (IrNO), Intermedine (Im), Intermedine-N-oxide (ImNO), Lasiocarpine (Lc), Lycopsamine (Ly), Lycopsamine-N-oxide (LyNO), Retrorsine (Rt), Retrorsine-N-oxide (RtNO), Rinderine (Rn), Rinderine-N-oxide (RnNO), Senecionine (Sn), Senecionine-N-oxide (SnNO), Seneciphylline (Sp), Seneciphylline-N-oxide (SpNO), Senecivernine (Sv), Senecivernine-N-oxide (SvNO), Senkirkine (Sk), Spartioidine (St), Spartioidine-N-oxide (StNO), Usaramine (Us) and Usaramine-N-oxide (UsNO). Methanol (LC-MS grade) was from VWR Chemicals (Rosny-sous-Bois-cedex, France), sulphuric acid (96%) and acetonitrile (LC-MS grade) were from Carlo Erba Reagents (Val de Reuil Cedex, France), formic acid was from Carlo Erba Reagents (Milan, Italy) and ammonium formate (analytical grade) was from Sigma-Aldrich (St. Louis, MO, USA). Ultrapure water used throughout the experiments was produced by an EvoQua Water Technologies system (Diessechem, Milan, Italy).
+ Open protocol
+ Expand
2

Analytical Characterization of Pyrrolizidine Alkaloids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lasiocarpine (Las) and lasiocarpine N-oxide were ordered from Cfm Oskar Tropitzsch (Marktredwitz, Germany). Lycopsamine (Lyc), Lycopsamine N-oxide, europine (Eur), europine N-oxide, senecionine (Sen), senecionine N-oxide, echimidine (Ech), echimidine N-oxide, intermedine, intermedine N-oxide, jacobine, jacobine N-oxide, heliosupine, heliosupine N-oxide, retrorsine N-oxide, retronecine, and senkirkine were obtained from Phytolab (Vestenbergsgreuth, Germany). Retrorsine (Ret) was delivered by AppliChem (Darmstadt, Germany). Methanol (MeOH, LC–MS grade) and water (H2O, LC–MS grade) were purchased from Merck KGA (Darmstadt, Germany). 7,9-Diglutathionyl-6,7-dihydro-1-hydroymethyl-5H-pyrrolizidine was obtained from ASCA (Berlin, Germany). Potassium cyanide (KCN), isotopically labeled potassium cyanide (KCX, K13C15N), glutathione and isotopically labeled glutathione (GSX, 13C215N-GSH), and all other chemicals and co-factors were purchased from Sigma-Aldrich (Steinheim, Germany). All chemicals were obtained in analytical grade, if available. Human liver microsomes (mixed gender from 50 donors; protein concentration 20 mg/mL; cytochrome P450 content 310 pmol/mg protein) and rat liver microsomes (male Sprague–Dawley rats; protein concentration 20 mg/mL; cytochrome P450 content 700 pmol/mg protein) were obtained from Corning (Corning, USA).
+ Open protocol
+ Expand
3

PA and PANO Reference Substances

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reference substances for 25 PA and PANO were purchased from Phytolab, Vestenbergsgreuth, Germany (echimidine, echimidine N-oxide, europine, europine N-oxide, erucifoline, erucifoline N-oxide, heliotrine, heliotrine N-oxide, intermedine, intermedine N-oxide, jacobine, jacobine N-oxide, lasiocarpine, lasiocarpine N-oxide, lycopsamine, lycopsamine N-oxide, monocrotaline, monocrotaline N-oxide, retrorsine, retrorsine N-oxide, senecionine, senecionine N-oxide, seneciphylline, seneciphylline N-oxide, and senkirkine). Stock solutions (c = 1.0 mg/mL) of each PA/PANO were prepared either with acetonitrile or acetonitrile/water (50/50, v/v), depending on the solubility, and stored at 4 °C in the dark. A PA/PANO mix solution (c = 1.0 µg/mL of each analyte) was used to prepare calibration standards and for the validation experiments. Water, acetonitrile and methanol were used in LC–MS grade (Th. Geyer, Renningen, Germany). Ammonia solution (32%) was purchased from Th. Geyer as well. Formic acid and ammonium formate used as eluent additive (LC–MS/MS grade) were from Sigma Aldrich (Deisenhofen, Germany).
+ Open protocol
+ Expand
4

Determination of Phytochemicals in Botanical Extracts

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solvents, chemicals, and reagents used for determination of PAs, chelidonic acid, glycyrrhizic acid, and apigenin 7-glucoside were purchased from Carl Roth, Merck, or Sigma-Aldrich in MS grade. Chemicals and reagents applied for imprinting were purchased by Sigma and Merck in the highest purity available. Intermedine (purity > 99 % by HPLC), lycopsamine (purity > 99 % by HPLC), retrors-ine (purity > 99 % by HPLC), senecionine (purity > 99 % by HPLC), senecyphilline (purity > 99 % by HPLC), senkirkine (purity > 98 % by HPLC), erucifoline (purity > 98 % by HPLC), senecivernine (purity > 95 % by HPLC), erucifoline-N-oxide (purity > 95 % by HPLC), retrosine-N-oxide (purity > 99 % by HPLC), senecyphilline-N-oxide (purity > 99 % by HPLC), senecivernine-N-oxide (purity > 99 % by HPLC), and chelidonic acid (purity > 98 % by HPLC) used as reference standards for quantification were purchased in the highest purity available from Phytolab. apigenin 7-glucoside (purity > 94 % by HPLC) and glycyrrhizic acid (purity > 72 % by HPLC) were supplied by EDQM.
+ Open protocol
+ Expand
5

Preparation and Storage of Pyrrolizidine Alkaloid Stock Solutions

Check if the same lab product or an alternative is used in the 5 most similar protocols
Senecionine (SEN, PhytoLab GmbH & Co. KG, Vestenbergsgreuth, Germany) and standard solutions of intermedine, lycopsamine, and heliotrine were kindly donated from SIA Analysis Laboratories (Izmir, Turkey). The stock solutions of SEN (1 mg/mL) were prepared by dissolving SEN in dimethyl sulfoxide (DMSO) or methanol. The stock solutions of other PAs—intermedine and lycopsamine—were dissolved in methanol, and heliotrine was dissolved in DMSO. All the stock solutions of PAs were stored at +4 °C in dark place for the required period in our study.
+ Open protocol
+ Expand
6

Pyrolizidine Alkaloid Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lasiocarpine (purity ≥ 95.0%, HPLC), riddelliine (purity ≥ 90.0%, HPLC), lycopsamine (purity ≥ 95.0%, HPLC), echimide (purity ≥ 90.0%, HPLC), and monocrotaline (purity ≥ 95.0%, HPLC) were purchased from Phytolab (Vestenbergsgreuth, Germany) (Fig. 1).

Chemical structures of PAs used in this study: Lasiocarpine, riddelliinee, monocrotaline, lycopsamine, and echimidine

+ Open protocol
+ Expand
7

Quantification of Pyrrolizidine Alkaloids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analytical standards were obtained from different suppliers as follows: echimidine (purity 97%), echimidine N-oxide (purity 97%), heliotrine (purity 91%), heliotrine N-oxide (purity 91%), lycopsamine (purity 80%) and lycopsamine N-oxide (purity 80%) from PhytoLab GmbH & Co. KG (Vestenbergsgreuth, Germany); senecionine (purity 99%), senecionine N-oxide (purity 99%), seneciphylline (purity 94%) and seneciphylline N-oxide (purity 94%) from Carl Roth & Co. KG (Karlsruhe, Germany); indicine-N-oxide (purity 99%), intermedine (purity 99%), jacobine (purity 98%), jacobine N-oxide (purity 98%), retrorsine (purity 90%), retrorsine N-oxide (purity 96.0%) and senkirkine (purity 98%) from Phytoplan (Heidelberg, Germany); caffeine (purity 98%), used as an internal standard, was from Sigma-Aldrich (Steinheim, Germany).
Methanol (LC-MS grade) and sulphuric acid (98% purity, analytical grade) were from Carlo Erba reagents (Milan, Italy). Ammonia (28% purity, analytical grade) was from VWR Chemicals. Formic acid (98% purity, LC-MS grade) was from Sigma-Aldrich. Ultra-pure water was obtained from a water purification system (Purelab Classic, ELGA Lab Water, High Wycombe, UK).
+ Open protocol
+ Expand
8

Quantification of Pyrrolizidine Alkaloids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analytical standards were obtained from different suppliers as follows: echimidine (purity 97%), echimidine N-oxide (purity 97%), heliotrine (purity 91%), heliotrine N-oxide (purity 91%), lycopsamine (purity 80%) and lycopsamine N-oxide (purity 80%) from PhytoLab GmbH & Co. KG (Vestenbergsgreuth, Germany); senecionine (purity 99%), senecionine N-oxide (purity 99%), seneciphylline (purity 94%) and seneciphylline N-oxide (purity 94%) from Carl Roth & Co. KG (Karlsruhe, Germany); indicine-N-oxide (purity 99%), intermedine (purity 99%), jacobine (purity 98%), jacobine N-oxide (purity 98%), retrorsine (purity 90%), retrorsine N-oxide (purity 96.0%) and senkirkine (purity 98%) from Phytoplan (Heidelberg, Germany); caffeine (purity 98%), used as an internal standard, was from Sigma-Aldrich (Steinheim, Germany).
Methanol (LC-MS grade) and sulphuric acid (98% purity, analytical grade) were from Carlo Erba reagents (Milan, Italy). Ammonia (28% purity, analytical grade) was from VWR Chemicals. Formic acid (98% purity, LC-MS grade) was from Sigma-Aldrich. Ultra-pure water was obtained from a water purification system (Purelab Classic, ELGA Lab Water, High Wycombe, UK).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!