The largest database of trusted experimental protocols

2 protocols using buv737 cd43

1

Monocyte-derived Macrophage Phenotyping

Check if the same lab product or an alternative is used in the 5 most similar protocols
Bone marrow cells were flushed from femurs and tibias, centrifuged, then exposed to geys buffer for 5 min on ice, incubated with Fc block (Murine TruStain FcX, Biolegend, 1/50 dilution) for 15 min, incubated with antibodies for 20 min at 4 °C, and washed before sorting CD115+/CD11c-/NK- monocytes using an Influx cell sorter (BD) [68 (link)]. Monocytes were cultured in complete RPMI medium (Thermo Fisher Scientific) and exposed to 100 ng/mL CSF1, 50 µM Q-VD-OPh and 50 µM Ac-YVAD-cmk. After five days, macrophages were studied by flow cytometry using AlexaFluor700-F4/80 (#MCA497A700, Bio-Rad), BV510-CD11b (#101245, Biolegend), PerCP/Cy5.5-CD11c (#560584, BD), APC/Cy7-GR1 (#108424, Biolegend), PE-CF594-SiglecF (#562757, BD), PE-CD71 (#113808, Biolegend), PE/Cy7-CD206 (#141720, Biolegend), APC-CD54 (#116120, Biolegend), PB-CD40 (#124626, Biolegend), BV711-CD64 (#139311, Biolegend), BV605-IA-IE (#563413, BD), BUV737-CD43 (#564398, BD). For the sorting of monocytes, the antibodies used were the following: APC-CD11b (#17-0112-83, Thermo Fisher Scientific), PE/Cy7-CD11c (#561022, BD), FITC-NK (#553164, BD), PerCP/Cy5.5-Ly6C (#560525, BD), AlexaFluor700-Ly6G (#561236, BD), biotin-CD115 (#135507, Biolegend), PE-Streptavidin (#554061, BD). The data were analyzed with FlowJo software v. 10.0.00003.
+ Open protocol
+ Expand
2

Interstitial Macrophages Identification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Right lungs were digested with the Lung Dissociation kit (Miltenyi Biotec), filtered, erythrocytes were removed using ACK and nucleated cells were collected. Cells were washed with ice-cold PBS, incubated with Fc block (Murine TruStain FcX, Biolegend, 1/50 dilution) for 15 min, incubated with the antibodies for 20 min at 4 °C, washed, then fluorescence was measured with a BD LSRFortessa X-20. Antibodies used were the following: AlexaFluor700-F4/80 (#MCA497A700, Bio-Rad), FITC-CD45 (#103108, Biolegend), BV510-CD11b (#101245, Biolegend), PerCP/Cy5.5-CD11c (#560584, BD), APC/Cy7-GR1 (#108424, Biolegend), PE-CF594-SiglecF (#562757, BD), PE-CD71 (#113808, Biolegend), PE/Cy7-CD206 (#141720, Biolegend), APC-CD54 (#116120, Biolegend), PB-CD40 (#124626, Biolegend), BV711-CD64 (#139311, Biolegend), BV605-IA-IE (#563413, BD), BV650-CD24 (#563545, BD), BUV737-CD43 (#564398, BD). The data were analyzed with FlowJo software v. 10.0.00003. Interstitial macrophages were selected according to their larger size (FSC) and granularity (SSC), on CD45 expression to select leukocytes and GR1-positive cells will be excluded to remove neutrophils, they are equally CD11b high, SiglecF negative, IA-IE positive and CD24 negative.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!