The largest database of trusted experimental protocols

5 protocols using 3 mercapto 1 propanol

1

Synthesis of Metal Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ethylene glycol, ethanol, and toluene were purchased from Samchun Chemicals (Republic of Korea). Poly(styrene-ethylene-butylene-styrene) (SEBS (H1041)) elastomer was obtained from Asahi Kasei (Japan). Silver nitrate, copper (II) chloride, poly(vinylpyrrolidone) (PVP, Mw, ~ 40 k and ~ 1,300 k), 1-Propanethiol, and 3-Mercapto-1-propanol were purchased from Sigma Aldrich (USA).
+ Open protocol
+ Expand
2

Polycrystalline Gold Electrode Functionalization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Polycrystalline
gold
electrodes (PGEs) of 2 mm diameter were purchased from IJ Cambria
Scientific Ltd. (Llanelli, UK). 3-Mercapto-1-propanol (MCP) was obtained
from Sigma-Aldrich (Dorset, UK). All other chemicals required were
purchased from Acros Organics (Thermo Fisher Scientific Ltd.) (Geel,
Belgium).
+ Open protocol
+ Expand
3

Functionalization and Characterization of TFV

Check if the same lab product or an alternative is used in the 5 most similar protocols
TFV was purchased from Ark Pharm, Inc. (Libertyville, IL). Bovine serum albumin (BSA), keyhole limpet hemocyanin (KLH), sulfosuccinimidyl 4-(N-maleimidomethyl)cyclohexane-1-carboxylate (sulfo-SMCC), 1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC), Pierce Protein G agarose beads, CarboxyLink Coupling Gel, Whatman chromatography paper, and pico chemiluminescent substrate were purchased from ThermoFisher (Waltham, MA). Amersham Protran nitrocellulose was purchased from GE Healthcare Life Sciences (Pittsburgh, PA). Anti-rabbit antibody conjugated to horseradish peroxidase (HRP) was purchased from GE Healthcare (Chicago, IL). Goat anti-rabbit antibody was purchased from Abcam (Cambridge, MA). N,N′-Dicyclohexylcarbodiimide (DCC), pyridine, 3-mercapto-1-propanol, silica gel Davisil grade 643, Hi-Flow Plus HF180 nitrocellulose sheets, adenosine monophosphate, Tween 20, sucrose, adenosine monophosphate (AMP), and all solvent and buffers were purchased from Sigma-Aldrich (St. Louis, MO). A 40nm InnovaCoat Gold Conjugation Kit was purchased from Innova Biosciences (Babraham, England).
+ Open protocol
+ Expand
4

Electrochemical Biosensing Reagent Preparation

Check if the same lab product or an alternative is used in the 5 most similar protocols
NaCl, KCl, KH2PO4, NaH2PO4, and NaOH were acquired from Fischer Scientific (NJ). H2SO4 was purchased from EMD (USA), and 2 mm gold electrodes, fritted Ag|AgCl electrodes, and platinum wire were from CHInstruments (TX). 6-Mercapto-1-hexanol, 11-mercapto-1-undecanol, 3-mercapto-1-propanol, tris(2-carboethyl)-phosphine hydrochloride (TCEP), cocaine, and murine monoclonal anti-FLAG M2 antibody were obtained from Sigma-Aldrich (MO). Kanamycin monosulfate was purchased from GoldBio.com (MO), and ethanol was obtained from Gold Shield Distributors (CA). 2 and 7/8″ microcloth, 1 μm monocrystalline diamond suspension, and 0.05 μm micropolish alumina powder were obtained from Buehler (IL). All were used as received.
+ Open protocol
+ Expand
5

Electrochemical Microheater Sensor Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chromium (99.99%) and gold (99.99%) used for the production of the microheater integrated electrode were purchased from Nanoovak (Turkey). Oligonucleotides were purchased from Sigma Aldrich, and the sequences are shown in Table 1. Control measurements (off-chip experiments) were performed using C223AT Screen Printed Electrodes (SPEs) with 1.6 mm gold working area purchased from Metrohm (Herisau, Switzerland). K4[Fe(CN)6]•3H2O (potassium ferrocyanide), K3[Fe(CN)6] (potassium ferricyanide), 3-Mercapto-1-propanol (MCP), tris(2-carboxyethyl)phosphine (TCEP), phosphate buffered saline (PBS), sulfuric acid (H2SO4) were purchased from Sigma Aldrich (USA). A PalmSens-P4 potenstiostat (PalmSens, Houten, Netherlands) was used to carry out EIS measurements.
Table 1. DNA sequences used for the experiment.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists