The largest database of trusted experimental protocols

Dionex ics 5000 capillary hpic system

Manufactured by Thermo Fisher Scientific

The Dionex™ ICS-5000+ Capillary HPIC™ System is a high-performance ion chromatography system designed for analysis of ions in aqueous samples. It features a capillary-scale separation system, enabling efficient, high-resolution separation and detection of inorganic anions, cations, and organic acids.

Automatically generated - may contain errors

2 protocols using dionex ics 5000 capillary hpic system

1

Carbohydrate Composition Analysis of Extracts

Check if the same lab product or an alternative is used in the 5 most similar protocols
The monomeric sugar composition of the extracts was determined according to Demuth et al. (15 (link)) by high-performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) after hydrolysis with trifluoracetic acid. The 10-mg sample materials were hydrolyzed with 2.5 ml 2 M TFA for 4 h at 100°C. The HPAEC-PAD separation was based on a procedure by Hardy et al. (31 (link)) and Rohrer et al. (32 (link)) with modifications. A Dionex™ ICS-5000+ Capillary HPIC™ System with a Dionex™ CarboPac™ PA1 IC column (Thermo Fischer Scientific AG, Basel, Switzerland) maintained at 26°C was used. The injection volume was 10 μl and the flowrate was 1 ml/min. Eluent (A) consisted of water and eluent (B) had 200 mM of NaOH. The gradient started with 92% (A) for 20 min. After 20 min, the gradient was changed to 100% (B) for 10 min, and finally re-equilibrated for 8 min with 92% (A). For the pulsed amperometric detection, replaceable gold electrodes were used in waveform A adapted from the Dionex technical note 21. All samples were measured in quintuplicates. L-(+)-arabinose and D-(+)-xylose as well as D-(+)-glucose and D-(+)-galactose were externally calibrated using a 13-point calibration from 1.25 to 100 μg/ml with 10 μg/ml of D-(–)-sorbitol as internal standard. Data processing was done in Chromeleon 7 (Thermo Fischer Scientific AG, Basel, Switzerland).
+ Open protocol
+ Expand
2

Anion Exchange Chromatography-Tandem Mass Spectrometry

Check if the same lab product or an alternative is used in the 5 most similar protocols
Anion exchange chromatography-tandem mass spectrometry was performed using a Dionex ICS-5000+ Capillary HPIC system (Thermo Scientific) coupled to a Q Exactive hybrid quadrupole-Orbitrap mass spectrometer (Thermo Scientific) as described (Walsby-Tickle et al., 2020 (link)).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!