The largest database of trusted experimental protocols

Titrinorm

Manufactured by Avantor
Sourced in United States, Belgium

TITRINORM® is a laboratory titration system designed for pH, conductivity, and redox potential measurements. It provides accurate and reliable results for various analytical applications.

Automatically generated - may contain errors

2 protocols using titrinorm

1

PVDF Membrane Fabrication and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
A commercially available polyvinylidene fluoride flat sheet microfiltration membrane (PVDF, ROTI®, 0.45 µm) was purchased from Carl Roth (Karlsruhe, Germany). In addition, the following chemicals were used: NaOH (1 M), perchloric acid (70%), and buffer solution pH 10 (TITRINORM®) from VWR (Radnor, PA, USA); tert-butyl alcohol (tBuOH, 99.5%) from Alfa Aesar (Karlsruhe, Germany); and nitrous oxide (N2O, 99.95%) from Air Liquide (Düsseldorf, Germany). Glycine, taurine, ethyl sodium sulfate (C2SS), dodecyl sodium sulfate (C12SS, SDS), tetramethylammonium bromide (C1TAB), and octyltrimethylammonium bromide (C8TAB) were obtained from Sigma-Aldrich (St. Louis, MO, USA). Furthermore, 2-aminoethyl methacrylate hydrochloride (AEMA, 90%, stabilized) from Acros Organics (Geel, Belgium) was used. Deionized water of Millipore® quality and EtOH (absolute; Merck, Darmstadt, Germany) were used for all steps. All chemicals were of analytical grade and used without further purification.
+ Open protocol
+ Expand
2

Non-Electrolyte Copper Samples Preparation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Non-electrolyte containing copper samples were prepared via dilution with a NC-solution (100 mM, in ACN), followed by the addition of an EDTA solution (0.1 M, disodium salt in aqueous solution, Titrinorm, VWR Chemicals, Leuven, Belgium). Afterward, ACN and running buffer were added to achieve an ACN concentration of 37.5 vol% for optimal solubility of the Cu + -NC-complex. The concentrations of NC and EDTA in the prepared sample were 12.5 mM, respectively.
Recovering of the electrolyte samples was conducted in a glovebox. The sample preparation with aqueous buffers was performed under inert atmosphere using argon counterflow to prevent oxidation of Cu + (Supporting Information).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!