The largest database of trusted experimental protocols

Heraeus labofuge 200 centrifuge

Manufactured by Thermo Fisher Scientific
Sourced in Germany

The Heraeus Labofuge 200 is a compact, general-purpose benchtop centrifuge. It is designed for routine sample preparation tasks in the laboratory. The Labofuge 200 can accommodate sample volumes up to 100 mL and has a maximum speed of 6,000 rpm.

Automatically generated - may contain errors

2 protocols using heraeus labofuge 200 centrifuge

1

Optimizing CRT Phosphor Leaching

Check if the same lab product or an alternative is used in the 5 most similar protocols
The leaching tests were performed in glass vials located on a mechanical shaker (TMS-200 Turbo Thermoshaker), unless otherwise specified. The roasted CRT phosphors were contacted with acetic acid and several parameters were varied in order to determine the optimal operative conditions. The agitation was kept constant at 2500 rpm in all the experiments. The leachate was separated from the solid residue through centrifugation (5300 rpm, 30 minutes, Thermo Scientific Heraeus Labofuge 200 centrifuge) and analysed by TXRF to determine the leaching efficiency EL (%), which was calculated according to eqn (1): where mL is the mass of the dissolved metal in the leachate (mg) and m0 is the mass of metal in the initial sample (mg). The leaching residue was further treated to recover yttrium and europium. To this aim, MSA was selected as leaching agent. Leaching tests were performed as a function of the lixiviant concentration, by keeping the temperature (T = 90 °C), the liquid-to-solid ratio (L/S = 20 mL g−1) and the contact time (t = 24 h) constant. Unless otherwise specified, each experiment was performed in duplicate.
+ Open protocol
+ Expand
2

Salivary Stress Biomarkers in Pigs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Saliva samples were collected to determine two salivary stress biomarkers, cortisol (CORT) and chromogranin A (CgA). Saliva samples were collected with the swab in the Salivette® tube (Sarstedt, Aktiengesellschaft & Co., Nümbrecht, Germany) to the pig’s mouth for 1 min. Sow samples were collected between 09:00 and 10:00, and piglet samples between 10:30 and 14:00. Samples were centrifuged (Heraeus™ Labofuge™ 200 Centrifuge; Thermo Fisher Scientific GmbH, Dreieich, Germany) for 10 min at 3000 rpm and stored at −20 °C until analysis. CORT was detected by the automated chemiluminescence immunoassay (Immulite 1000 cortisol; Siemens Medical Solutions Diagnostics, Los Angeles, CA, USA) and CgA by the time-resolved immunofluorometry assays (TR-IFMA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!