The largest database of trusted experimental protocols

Flash purification system

Manufactured by Biotage
Sourced in United States

The Flash Purification System is a laboratory equipment designed for rapid and efficient purification of chemical compounds. It utilizes flash chromatography, a technique that separates mixtures based on the differences in the relative affinities of the components for a stationary and a mobile phase. The system automates the purification process, providing a reliable and reproducible method for researchers and chemists to isolate and purify their target compounds.

Automatically generated - may contain errors

2 protocols using flash purification system

1

Synthesis of Iodinated Molecule 11 from Precursor 10

Check if the same lab product or an alternative is used in the 5 most similar protocols
To a 10 mL MeOH solution containing 100 mg (0.196 mmol) of 10 was added 149 mg (0.432 mmol; 50% purity) mCPBA. The resultant solution was heated at 70 °C in a microwave reactor for 20 min. The conversion of 10 to 11 was followed by HPLC. The reaction mixture was evaporated to dryness using rotary evaporator under vacuum. The crude 11 was dissolved in 1:1 MeOH:H2O and purified using Biotage Flash Purification System (Charlottesville, VA, USA) to yield 14 mg (13.2%). 1H NMR (DMSO-d6): δ 2.23 (t, 2H, J = 6.2 Hz), 2.79 (t, 2H, J = 5.7 Hz), 3.46–3.53 (m, 15H), 3.57 (t, 2H, J = 6.2 Hz), 3.89 (s, 3H), 8.08–8.14 (m, 4H). HRMS (ES+): C19H28INNaO9 (M+Na)+ Calcd: 564.0707 Found: 564.0762. HPLC tR = 5.0 min.
+ Open protocol
+ Expand
2

Characterization of Organic Compounds using NMR and HPLC

Check if the same lab product or an alternative is used in the 5 most similar protocols
All chemicals were purchased from Sigma-Aldrich, Acros Chemicals, Fluorochem or Alfa Aesar and used without further purification unless otherwise stated. Anhydrous acetonitrile was obtained from a MBraun SPS800 solvent purification system unless otherwise stated. Flash column chromatography was performed using Biotage Flash Purification system. 1H NMR and 13C NMR spectra were measured on a Bruker Avance 500 NMR spectrometer and Bruker Avance DPX400 spectrometer. 1H NMR and 13C NMR spectra are reported as chemical shifts in ppm downfield from TMS and J values are given in Hertz. 31P NMR spectra were recorded on Bruker Avance DPX400 spectrometer or Bruker Avance 500 NMR spectrometer and are reported in chemical shifts downfield from 85% H3PO4. Reverse phase HPLC was performed on a system comprising of a Dionex P680 pump and a Dionex UVD170U detector unit.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!