The largest database of trusted experimental protocols

Agilent 7890b 5977a 7693autosampler series gas chromatograph

Manufactured by Agilent Technologies
Sourced in United States

The Agilent 7890B/5977A/7693Autosampler Series Gas Chromatograph is a high-performance analytical instrument designed for the separation and analysis of complex chemical mixtures. It features a gas chromatograph coupled with a mass spectrometer detector, as well as an automated liquid sample injection system. The system is capable of precise separation, identification, and quantification of a wide range of organic compounds.

Automatically generated - may contain errors

3 protocols using agilent 7890b 5977a 7693autosampler series gas chromatograph

1

GC-MS Analysis of Pomegranate Seed Oil

Check if the same lab product or an alternative is used in the 5 most similar protocols
The GC-MS analysis of pomegranate seed oil was performed according to Wang et al. (2014) . The experiment was performed using an Agilent 7890B/5977A/7693
Autosampler Series Gas Chromatograph (Agilent Technologies, Palo Alto, CA) using a DB-WAX capillary column (30 m × 0.25 mm × 0.25 mm film thickness, Hewlett Packard, USA).
+ Open protocol
+ Expand
2

Profiling Egg Yolk Fatty Acids by GC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
The fatty acid methyl ester (FAME) of egg yolk lipid was studied using gas
chromatography - mass spectrometry (GC-MS) (Wang
et al., 2014
). Using a DB-WAX capillary column, the experiment was
carried out on an Agilent 7890B/5977A/7693 Autosampler Series Gas Chromatograph
(Agilent Technologies, Palo Alto, CA, USA; 30 m×0.25 mm×0.25 mm
film thickness, Agilent Technologies). Split injection at a ratio of 10:1 was
used to evaluate the experiment, with ultra-high purity helium as the carrier
gas and a flow rate of 1.0 mL/min. Temperatures for the injector and detector
were 250°C and 260°C, respectively. The temperature was set at
150°C for 0 min, then increased to 230°C at a rate of
10°C/min for 15 min. The experiment lasted 23 min, and the injection
amount was 0.2 mL. The mass spectrometer was operated in electron impact mode
with continuous scanning from m/z 50 to 500 at 70 eV of ionization voltage. By
comparing the mass spectrum data to the NIST 11 library database and referring
the literature, the detection of FAME in egg yolk lipid was investigated. Only
components having a resemblance of greater than 60% (highest similarity
is 100%) were included in this study.
+ Open protocol
+ Expand
3

GC-MS Analysis of Pomegranate Seed Oil

Check if the same lab product or an alternative is used in the 5 most similar protocols
The GC-MS analysis of pomegranate seed oil was performed according to Wang et al. (2014) . The experiment was performed using an Agilent 7890B/5977A/7693
Autosampler Series Gas Chromatograph (Agilent Technologies, Palo Alto, CA) using a DB-WAX capillary column (30 m × 0.25 mm × 0.25 mm film thickness, Hewlett Packard, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!