Microscopic Examination of Spider Specimens

Check if the same lab product or an alternative is used in the 5 most similar protocols
All the specimens were collected by sifting leaf litter. The specimens were examined using a Leica M205C stereomicroscope. Details were studied under an Olympus BX51 compound microscope. All illustrations were made using a drawing tube and inked on ink jet plotter paper. Photos were made with a Canon EOS 550D zoom digital camera (18 mega pixels) mounted on an Olympus BX51 compound microscope. Vulvae were cleared in lactic acid. Male palps and chelicerae were mounted in Kaiser’s glycerol gelatin. All measurements were taken using an Olympus BX51 compound microscope and are in millimeters.
The following abbreviations are used in the text: ALE

= anterior lateral eyes

; PLE

= posterior lateral eyes

; PME

= posterior median eyes

.
All types of the new species are deposited in

Lee Kong Chian Natural History Museum, National University of Singapore

(LKCNHM)
. Other material studied is deposited in

Shenyang Normal University

(SYNU)
in Shenyang, China.
+ Open protocol
+ Expand
2

Microscopic Examination of Spider Specimens

Check if the same lab product or an alternative is used in the 5 most similar protocols
The specimens were examined using a Leica M205C stereomicroscope. Details were studied under an Olympus BX51 compound microscope. Photos were made with a Canon EOS 550D zoom digital camera (18 megapixels) mounted on an Olympus BX51 compound microscope. Vulvae were cleared in lactic acid. For scanning electron microscopy (SEM), specimens were air-dried, sputter-coated using IXRF SYSTEMS, and imaged with a Hitachi TM3030 SEM. All measurements were taken using an Olympus BX51 compound microscope and are in millimeters. The type material is deposited in Shenyang Normal University (SYNU) in Shenyang, China.
The following abbreviations are used in the text and figures: a = apodemes; ALE = anterior lateral eyes; cd = copulatory duct; dp = dorsal process; PLE = posterior lateral eyes; PME = posterior median eyes; po = pore; pp = prolateral process; rp = retrolateral process; ss = star-shaped structure; ssc = stick-shaped sclerite; trs = transverse sclerites; vp = ventral process; vsp = ventral small process; wa = wing-shaped appendices; XTBG = Xishuangbanna Tropical Botanical Garden.
+ Open protocol
+ Expand
3

Detailed Microscopy and Measurement Protocol for Spider Specimens

Check if the same lab product or an alternative is used in the 5 most similar protocols
The specimens were examined using a Leica M205C stereomicroscope. Details were studied under an Olympus BX51 compound microscope. Photos were made with a Canon EOS 550D zoom digital camera (18 megapixels) mounted on an Olympus BX51 compound microscope. Vulvae were cleared in lactic acid. Scanning electron microscope images (SEM) were taken under high vacuum with a Hitachi TM3030 after critical point drying and gold-palladium coating. All measurements were taken using an Olympus BX51 compound microscope and are in millimeters. The type material is deposited in the Institute of Zoology, Chinese Academy of Sciences in Beijing (IZCAS).
The following abbreviations are used in the text and figures: ALE = anterior lateral eyes; ap = apodeme; bls = brush-like structures; dl = dorsal lobe; hss = horseshoe-shaped sclerite; ldi = labium deep incision; pl = posterior lobe; PLE = posterior lateral eyes; PME = posterior median eyes; pr = posterior receptaculum; tls = tube-like structure; tsc = T-shaped sclerite; vl = ventral lobe.
+ Open protocol
+ Expand
4

Detailed Microscopic Examination of Specimens

Check if the same lab product or an alternative is used in the 5 most similar protocols
The specimens were examined using a Leica M205C stereomicroscope. Details were studied under an Olympus BX51 compound microscope. Photos were made with a Canon EOS 550D zoom digital camera (18 megapixels) mounted on an Olympus BX51 compound microscope. Vulvae were cleared in lactic acid. For scanning electron microscopy (SEM), specimens were air-dried, sputter coated using IXRF SYSTEMS, and imaged with a Hitachi TM3030 SEM. All measurements were taken using an Olympus BX51 compound microscope and are in millimeters. The type material is deposited in Shenyang Normal University (SYNU) in Shenyang, China (curator: Yanfeng Tong).
The following abbreviations are used in the text and figures: ALE = anterior lateral eyes; am = anterior membrane; ami = anterior median indentation; ap = anterior protrusion; apo = apodemes; bp = basal protrusion; csp = cone-shaped protuberance; dp = distal protrusion; lt = large tooth; PLE= posterior lateral eyes; pm = posterior membrane; PME = posterior lateral eyes; pp = posterior protrusion; pr = posterior receptaculum; ss = slit sensillum; tls = tube-like structure; tsc = T-shaped sclerite.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!