The largest database of trusted experimental protocols

Wako diagnostics kits for cholesterol e

Manufactured by Fujifilm

The Wako Diagnostics kits for Cholesterol E are laboratory equipment used to measure cholesterol levels. These kits provide a quantitative analysis of cholesterol in biological samples.

Automatically generated - may contain errors

2 protocols using wako diagnostics kits for cholesterol e

1

Serum and Plasma Collection Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
For serum collection, tubes of blood were removed from the ice and left at room temperature for 30 minutes to clot; then, the clots were dislodged using p200 pipette tips. For plasma collection, retroorbital blood draws were performed using microhematocrit capillary tubes (Thermo Fisher Scientific, 22-362566) and collected in heparinized microtainers (BD Biosciences, 365965). Blood samples were spun down in a tabletop centrifuge for 10 minutes at 4°C and 10,000g. The supernatant (serum or plasma) was removed from the tube and transferred to a new Eppendorf for storage at –80°C until analysis.
Serum was analyzed in batches for total cholesterol to confirm that animals in the atherogenic arm of the study responded to the AAV-m-PCSK9 and high-fat/high-cholesterol diet. FujiFilm Wako Diagnostics kits for Cholesterol E (no. 999-02601) were used according to manufacturer recommendations. Samples were diluted down 1:10 in sterile water so they fell on the standard curve. All tests were completed in triplicate.
+ Open protocol
+ Expand
2

Serum and Plasma Collection for Cholesterol Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
For serum collection, tubes of blood were removed from the ice and left at room temperature for 30 minutes to clot, then the clots were dislodged using p200 pipette tips. For plasma collection, retroorbital blood draws were performed using microhematocrit capillary tubes (Fisherbrand 22–362566) and collected in heparinized microtainers (BD 365965). Blood samples were spun down in a tabletop centrifuge for 10 minutes at 4°C and 10,000 G. The supernatant (serum or plasma) was removed from the tube and transferred to a new Eppendorf for storage at −80°C until analysis.
Serum was analyzed in batches for total cholesterol to confirm that animals in the atherogenic arm of the study responded to the AAV-m-PCSK9 and high fat/high cholesterol diet. FujiFilm Wako Diagnostics kits for Cholesterol E (999–02601) were used according to manufacturer recommendations. Samples were diluted down 1:10 in sterile water so they fell on the standard curve. All tests were completed in triplicate.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!