The largest database of trusted experimental protocols

2 protocols using cd45ra vioblue

1

Multiparametric Flow Cytometry Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following mAbs were used for staining and flow cytometric measurements: CD3-VioGreen (BW264/56), CD4-allophycocyanin-Vio770 (VIT4), CD8-PE-Vio770 (BW135/80), CD14-peridinin chlorophyll protein (PerCP) (TÜK4), CD20-PerCP (LT20), CD27-FITC (M-T271), CD28-FITC (15E8), CD45RA-VioBlue (T6D11), CD45RO-FITC (UCHL1), CD62L-FITC (145/15), CD107a-PE (1D4B), CD127-FITC (MB15-18C9), CD137-allophycocyanin, CD137-PE (4B4-1), CD154-VioBlue (5C8), CD178-PE (NOK-1), CD197 (CCR7)-allophycocyanin, CD197 (CCR7)-PE (150503), CD279-allophycocyanin (PD1.3.1.3), anti-IL-2-PE-Vio770 (N7.48A), anti-IL-4-PE (7A3-3), anti-IL-17-FITC (CZ8-23G1), anti-IFN-γ-FITC, anti-IFN-γ-PE-Vio770 (45-15), anti-TNF-α-PE, and anti-TNF-α-VioBlue (cA2) (all Miltenyi Biotec).
Soluble biotinylated pHLA-A*0201 molecules loaded with WT137 (VLDFAPPGA), WT1126 (RMFPNAPYL), WT1187 (SLGEQQYSV), WT1235 (CMTWNQMNL), or cytomegalovirus (CMV) pp65495 (NLVPMVATV) were produced as described previously.14 (link) Tetramerization was achieved by binding to streptavidin-PE or streptavidin-allophycocyanin (both BioLegend, San Diego, CA). In each case, 2·5 × 106 cells were stained with 1 µg/ml tetramer for 45 min at 4°C.
Data were acquired using a MACSQuant flow cytometer and analysed with MACSQuantify software (both Miltenyi Biotec).
+ Open protocol
+ Expand
2

Profiling Myeloid Cells in HIV-1 Infection

Check if the same lab product or an alternative is used in the 5 most similar protocols
Peripheral blood mononuclear cells (PBMC) were isolated from HIV-1-infected patients (approved by Comité de protection des personnes CPP, ID-RCB 2017-A02820-53) or from controls (approved by the Institut National de la Santé et de la Recherche Médicale ethics committee) with Ficoll-Paque PLUS (GE). Informed consent was obtained from all donors, and samples were de-identified prior to use in the study. Total blood DCs were enriched with EasySep human pan-DC pre-enrichment kit (Stemcell Technologies 19251). DC enriched fraction were stained with antibodies specific for HLA-DR APCeFluor780, CD1c PerCPeFluor710 (eBioscience), CD123 Viogreen, CD45RA Vioblue, CD169 (Siglec-1) PE-Vio770 (Miltenyi), Axl PE (Clone #108724, R&D Systems), CD33 PE-CF594, CD141 BV711 (BD) and with a cocktail of antibodies against lineage markers CD19 (Miltenyi), CD3, CD14, CD16 and CD34 (BD) in the FITC channel. Data was acquired on a on a FACS Aria using Diva software (BD) and analysed in FlowJo v10 and GraphPad prism v7 for Mac.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.