The largest database of trusted experimental protocols

Glucose oxidase liquid stable reagent

Manufactured by Thermo Fisher Scientific
Sourced in United States

Glucose Oxidase Liquid Stable Reagent is a laboratory product used for the determination of glucose concentration in various sample types. The reagent contains glucose oxidase, an enzyme that catalyzes the oxidation of glucose to gluconic acid and hydrogen peroxide. The generated hydrogen peroxide is then measured colorimetrically, providing a quantitative assessment of the glucose content.

Automatically generated - may contain errors

2 protocols using glucose oxidase liquid stable reagent

1

Cholesterol, Triglyceride, and Glucose Quantification in Flies

Check if the same lab product or an alternative is used in the 5 most similar protocols
For cholesterol determinations, two flies were washed in Danieau’s solution pH 7.2 (17.4 mM NaCl, 0.21 mM KCl, 0.12 mM MgSO4+H20, 0.18 mM Ca(NO)3, 1.5 mM HEPES) and homogenized in 200 μl of PBST containing 0.05% Tween 20 (Apex Bioresearch Products, Genesee Scientific El Cajon, CA #18–173). Total cholesterol was measured in triplicate using the Infinity Cholesterol Liquid Stable Reagent (Thermo Fischer Scientific Waltham, MA #T1213421). Cholesterol was quantified according to manufacturer’s instructions and were read using a SpectraMax i3 plate reader (Molecular Devices, San Jose, CA). To determine triglycerides, single flies were washed in Danieau’s solution and homogenized in 200 μL PBST. Samples were diluted 1:10 in PBST and total triglyceride was measured in triplicate using the Infinity Triglyceride reagent (Thermo Fischer Scientific Waltham, MA #TR22421). Triglyceride was quantified according to manufacturer’s instructions using a SpectraMax i3 plate reader. Glucose was determined using single flies washed in Danieau’s solution and homogenized in 500 μl of 100 mM maleate buffer, pH 5.5 (Alfa Aesar Haverhill, MA #J62049). Total glucose was measure in triplicate using the Glucose Oxidase Liquid Stable Reagent (Thermo Fischer Scientific Waltham, MA TR15221). Glucose was measured according to manufacturer’s instructions and read using a SpectraMax i3 plate reader.
+ Open protocol
+ Expand
2

Plasma Metabolite Levels in Rat Models

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma levels of triglycerides, cholesterol, and glucose were measured in ZLN and ZOF rats before (control) and 3 days after mt-tat-ExoIII (ZLN) or mt-tat-EndoIII treatment (ZOF). Triglyceride Liquid Stable Reagent, Cholesterol Liquid Stable Reagent and Glucose Oxidase Liquid Stable Reagent from Infinity (Thermo Fisher Scientific, Waltham, MA, USA) were used according to the manufacturer’s instructions.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!