The largest database of trusted experimental protocols

Poly ethylene glycol block poly propylene glycol block poly ethylene glycol peg ppg peg

Manufactured by Merck Group

Poly(ethylene glycol)-block-poly(propylene glycol)-block-poly(ethylene glycol) (PEG-PPG-PEG) is a triblock copolymer composed of polyethylene glycol (PEG) and polypropylene glycol (PPG) segments. It is a lab equipment product used for various applications.

Automatically generated - may contain errors

2 protocols using poly ethylene glycol block poly propylene glycol block poly ethylene glycol peg ppg peg

1

Synthesis of Conductive Polymer Composites

Check if the same lab product or an alternative is used in the 5 most similar protocols
Monodispersed suspension of PS nanospheres (10 wt%, in water) with various diameters (100, 300, and 600 nm), sodium dodecyl sulfate (SDS, ≥99%), 3,4-ethylenedioxythiophene (EDOT, 97%), poly(ethylene glycol)-block-poly(propylene glycol)-block-poly(ethylene glycol) (PEG-PPG-PEG, Mw = 5800), dimethylformamide (DMF), n-butanol and toluene were purchased from Sigma-Aldrich. Iron (III) tosylate (Fe(Tos)3, 40 wt%, in n-butanol) (CleviosTM C-B 40 V2) were purchased from H.C. Starck. P-type Bi2Te3 powders (99.99%, ~1250 mesh) were purchased from KYD Materials. Silicon wafers (undoped, resistivity ρ > 10,000 ohm cm) were purchased from University Wafer. Flexible polyimide substrates were purchased from Gizmodorks. All the materials were used as received.
+ Open protocol
+ Expand
2

Fabrication of Porous PCL Scaffolds

Check if the same lab product or an alternative is used in the 5 most similar protocols
3D printed macroporous medical grade PCL scaffolds with porosity of 70% were purchased from Osteopore TM . Circular samples (12 mm diameter) were cut out of the 5 x 5 cm sheet using a metallic hole-puncher. PCL films (to be used for FTIR and contact angle measurements) were thermally pressed into a thickness of approximately 120 µm. Briefly, a known mass of PCL was placed between two stainless steel sheets on a Carver bench press (Carver Inc, USA). Temperature was elevated to 100 °C and pressure exerted for 30 min. The pressed film was then allowed to cool to room temperature via normal convection cooling.
Clevios™ CB 40 V2 (40% wt/wt Fe(III) p-toluenesulfonate (Tosylate) in butanol) was purchased from Heraeus (Germany). 3,4-Ethylenedioxythiophene (EDOT) monomer (142.18 g/mol), pyridine (79.10 g/mol), and the triblock copolymer poly(ethylene glycol)-block-poly(propylene glycol)-blockpoly(ethylene glycol) (PEG-PPG-PEG, 5800 g/mol) were purchased from Sigma-Aldrich. All chemicals were used as received without further purification.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!