The largest database of trusted experimental protocols

Masslynx ver 4

Manufactured by Waters Corporation
Sourced in United Kingdom

MassLynx ver. 4.1 is a software developed by Waters Corporation. It is used for the control and data analysis of mass spectrometry instrumentation.

Automatically generated - may contain errors

2 protocols using masslynx ver 4

1

Targeted LC-MS/MS Analysis of Homeostatic Lipids

Check if the same lab product or an alternative is used in the 5 most similar protocols
We used a Xevo TQ-S mass spectrometer equipped with Acquity I Class UPLC (Waters Corporation, Milford, MA). CORTECS C18 column (2.7 µm particle size, 4.6 mm × 100 mm i.d.) (Waters Corporation, #186007377) for the separation of fatty acids and their derivatives. LC conditions are as follow; 45% of solvent A (H2O + 0.01% acetic acid) and 55% of solvent B (MeOH + 0.01% acetic acid) with a flow rate of 0.6 mL/min was initially set at 0 min., then gradient was set for 85% B at 10 min, 98% B at 18 min, 100% B at 20 min, back to 55% B at 30 min. The capillary voltage was −2.5 kV, desolvation temperature was 600 °C, desolvation gas flow was 1100 L/h, cone gas was 150 L/h, and nebulizer pressure was 7.0 bar with a source temperature of 150 °C. MassLynx ver. 4.1 software (Waters Corporation) was used for the operation and recording of the data. Data were expressed as the change in the relative abundance of pro-homeostatic lipid mediators normalized with the internal standards.
+ Open protocol
+ Expand
2

Ionization and Fragmentation Analysis of Erlotinib and Moxifloxacin

Check if the same lab product or an alternative is used in the 5 most similar protocols
Erlotinib and moxifloxacin were ionised using a Waters solids probe (Waters Corp., Milford, MA, USA). Samples were left to dry at ambient temperature on a glass capillary inserted into the solids probe before it was placed inside the mass spectrometer Waters GTC Premier micromass (Waters Corp., Milford, MA, USA). The temperature was gradually increased in 10 K steps until fragment ions were observed from the molecular ion. Data acquisition and processing were carried out using MassLynx (ver. 4.1) software (Waters Corporation, Manchester, UK). The instrument was calibrated using heptacosafluorotributylamine to a mass range of m/z 49.996 to m/z 613.694. EI spectra of
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!