The largest database of trusted experimental protocols

Single beam silicon cantilever probes

Manufactured by Olympus
Sourced in Japan

Single-beam silicon cantilever probes are a type of lab equipment used for various scientific applications. They consist of a silicon cantilever with a sharp tip at one end, designed to interact with a sample surface. The core function of these probes is to measure surface topography, adhesion, and other properties at the nanoscale.

Automatically generated - may contain errors

2 protocols using single beam silicon cantilever probes

1

Atomic Force Microscopy of Alpha-Synuclein

Check if the same lab product or an alternative is used in the 5 most similar protocols
10 μL purified αSOs were added to freshly cleaved mica and allowed to adsorb for 5 min at RT. Unbound protein was gently washed off with Millipore-filtered water (3x 50 μL), dried under a gentle stream of nitrogen and imaged immediately on a MultiMode Nanoscope IIIa microscope (Digital Instruments, USA) equipped with an E-scanner. All measurements were carried out in tapping mode under ambient conditions using single-beam silicon cantilever probes with a resonance frequency of 300 kHz (Olympus, Japan). AFM images were captured with a resolution of 512 samples/line at a scan rate of 1 Hz, with scan sizes of 2x2 μm. Raw data images were processed using Gwyddion software (V2.37) by levelling the data and shifting minimum data values to zero. To determine αSO heights, ~150 αSOs from three different regions were analysed.
+ Open protocol
+ Expand
2

AFM Imaging of α-Synuclein Fibrils

Check if the same lab product or an alternative is used in the 5 most similar protocols
Labeled α-syn fibrillar samples were diluted 5 times into PBS, and 10 μL were pipetted onto freshly cleaved mica and kept at room temperature for 60 s. The mica surface was then rinsed with Millipore-filtered water (2×50 03BCL) to remove loosely bound protein, dried under a stream of nitrogen and imaged immediately. AFM imaging was performed on a MultiMode Nanoscope IIIa microscope (Digital Instruments, USA) equipped with an E-scanner. All measurements were carried out in the tapping mode under ambient conditions using single-beam silicon cantilever probes with a resonant frequency of 300 kHz (Olympus, Japan). Image analysis was performed using the instrument software.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.