The largest database of trusted experimental protocols

Quantity one software ver 4.6.9

Manufactured by Bio-Rad

Quantity One software ver. 4.6.9. is a data analysis software developed by Bio-Rad. The software is designed to quantify and analyze 1D gel and blot images.

Automatically generated - may contain errors

2 protocols using quantity one software ver 4.6.9

1

Rice Protein Extraction and SDS-PAGE

Check if the same lab product or an alternative is used in the 5 most similar protocols
A previous report outlined the process of protein extraction from rice powder and the method of moderate denaturation to achieve higher resolution SDS-PAGE results (Takahashi et al. 2019 (link)). SDS-PAGE was performed using 15% polyacrylamide gels (ATTO, Tokyo, Japan) with protein-size markers (Bio-Rad, Hercules, MA, USA). After separation, the proteins were stained with 0.1% Coomassie Brilliant Blue (CBB) R-250 (Nacalai tesque, Kyoto, Japan). The gel was destained for at least 3 h before being scanned directly. Quantity One software ver. 4.6.9. (Bio-Rad) was used to determine the intensity of TP intensity in a lane, glutelin acidic subunit, glutelin basic subunit, and prolamin. The ratios of glutelin (G) / TP, prolamin (P) / TP, and other proteins / TP were calculated as follows:
+ Open protocol
+ Expand
2

Protein Analysis by SDS-PAGE and Immunoblotting

Check if the same lab product or an alternative is used in the 5 most similar protocols
SDS–PAGE was performed using 15% polyacrylamide gels (ATTO) with protein size markers (Bio-Rad, Hercules, MA, USA). After separation, the proteins were stained with 0.1% Coomassie brilliant blue (CBB) R-250. The gel was destained for at least 3 h before being directly scanned using an EPSON GT 900 scanner (Nagano, Japan).
For immunoblot analysis, proteins were transferred from gels to 0.22-μm pore PVDF membranes (Whatman) at 12 V, 60 mA, for 30 min. The membrane was soaked in blocking buffer (Nacalai tesque, Inc., Kyoto, Japan). After incubation with target primary antibodies (1/1000–1/8000 dilution), the membrane was washed three times with PBS-containing Tween 20. The membrane was incubated with secondary antibodies conjugated with HRP before being washed a further three times with PBS-containing Tween 20. Proteins were detected by chemical luminescence (ECL prime, GE Healthcare Japan, Tokyo, Japan) using either an LAS 1000 (GE Healthcare) or ChemiDoc™ MP imaging system (Bio-Rad). QuantityOne software ver. 4.6.9. (Bio-Rad) was used to determine the intensity of detected protein bands.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!