The largest database of trusted experimental protocols

Elecsys tsh kit

Manufactured by Roche

The Elecsys TSH kit is a laboratory test used to measure the levels of thyroid-stimulating hormone (TSH) in a patient's blood sample. TSH is a hormone produced by the pituitary gland that regulates the function of the thyroid gland. The Elecsys TSH kit provides a quantitative measurement of TSH levels, which is important for the diagnosis and management of thyroid disorders.

Automatically generated - may contain errors

4 protocols using elecsys tsh kit

1

Maternal Thyroid Function Monitoring

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fasting maternal venous blood samples were obtained on the day of electronic impedance cardiography monitoring. Samples were centrifuged, and supernatants were stored at − 80 °C. TSH was measured using an Elecsys-TSH kit (Roche Diagnostics, Mannheim, Germany, RRID:AB_2756377). FT4 was measured using an FT4 Flex reagent (Siemens, Berlin, Germany, RRID:AB_2801666). Thyroid peroxidase antibody was measured with an E-Anti-TPO kit (Roche Diagnostics, Mannheim, Germany, RRID:AB_10698637) and was graded as positive when greater than 60 IU/ml. The normal reference for TSH in the third trimester was 0.3 to 3.5 mIU/L, as recommended [21 (link)].
+ Open protocol
+ Expand
2

Thyroid Function and Autoantibody Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Thyroid function tests which consisted of serum free T3 (fT3), free T4 (fT4), and TSH levels were performed using electrochemiluminescent immunoassay (Elecsys FT3 II kit, Elecsys FT4 kit, and Elecsys TSH kit, respectively; Roche Diagnostics, Mannheim, Germany); the reference ranges were 2.33–4.00 pg/mL, 0.880–1.620 ng/dL, and 0.500–5.000 μIU/mL, respectively. Levels of anti-thyroperoxidase antibodies (TPOAbs) and anti-thyroglobulin antibodies (TgAbs) were also measured using electrochemiluminescent immunoassay (Elecsys Anti-TPO kit and Elecsys Anti-Tg kit, respectively; Roche Diagnostics). Thyroid uptake of FDG-PET was defined as diffusely increased FDG uptake in the thyroid gland.
+ Open protocol
+ Expand
3

Thyroid Function Biomarker Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum levels of free T3 (fT3), free T4 (fT4), and TSH were measured with electrochemiluminescence immunoassays. During the period analyzed in the retrospective study, Elecsys kits were used (Elecsys FT3 II kit, Elecsys FT4 kit, and Elecsys TSH kit; Roche Diagnostics, Mannheim, Germany), and the reference ranges were 2.33-4.00 pg/mL, 0.880-1.620 ng/dL, and 0.500-5.000 μIU/mL, respectively. In the case series, AIA kits were used (AIA-PACK CL FT3 kit, AIA-PACK CL FT4 kit, and AIA-PACK CL TSH kit; Tosoh, Tokyo, Japan), and the reference ranges were 2.06-3.17 pg/mL, 0.880-1.620 ng/dL, and 0.500-5.000 μIU/mL, respectively. TgAb, TPOAb, and anti-TSH receptor antibody (TRAb) were measured using Elecsys kits (Roche Diagnostics), with reference ranges of <28 IU/L, <16 IU/L, and <2.0 IU/L, respectively. Measurement of thyroid stimulating antibody (TSAb) titers was performed using a TSAb enzyme immunoassay kit (Yamasa Corp., Chiba, Japan), with a cut-off level of 120%.
+ Open protocol
+ Expand
4

Comprehensive Thyroid Function Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum levels of free T3 (fT3), free T4 (fT4), TSH, and thyroglobulin (Tg) were measured with electrochemiluminescence immunoassays (Elecsys FT3 II kit, Elecsys FT4 kit, Elecsys TSH kit, and Elecsys Tg II kit, respectively; Roche Diagnostics, Mannheim, Germany). The reference ranges were 2.33-4.00 pg/mL, 0.880-1.620 ng/dL, 0.500-5.000 μIU/mL, and <33.7 ng/mL respectively. Anti-thyroid peroxidase antibody (TPOAb), anti-thyroglobulin antibody (TgAb), and anti-TSH receptor antibody (TRAb) were measured using Elecsys kits (Roche Diagnostics). The reference ranges were <16 IU/L, <28 IU/L, and <2.0 IU/L, respectively. Measurement of thyroid stimulating antibody (TSAb) titers was performed using a TSAb enzyme immunoassay kit (Yamasa Corp., Chiba, Japan); the cut-off level was 120%.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!